HVAD Waveform Analysis as a Noninvasive Marker of Pulmonary Capillary Wedge Pressure: A First Step Toward the Development of a Smart Left Ventricular Assist Device Pump.
نویسندگان
چکیده
Flow waveforms are an important feature of the HVAD left ventricular assist device (LVAD) that provides information about HVAD function and patient hemodynamics. We assessed the properties of one specific aspect of the waveform, the slope of the ventricular filling phase (VFP), and its correlation with pulmonary capillary wedge pressure (PCWP). A total of 101 screenshots from the HVAD monitor and simultaneous hemodynamic measurements were obtained simultaneously during sequential stages of invasive hemodynamic ramp studies. Each screenshot was digitized (IGOR Pro, WaveMetrics Inc., Oswego, OR) and properties of the flow waveforms including instantaneous flow and rate of change of flow were analyzed. Ventricular filling phase slope (VFPS) was calculated for each screenshot and correlated to PCWP. Ventricular filling phase slope was significantly higher in patients with PCWP ≥ 18 mm Hg than in patients with PCWP < 18 mm Hg [6.25 (5.84-7.37) L/min/s vs. 3.27 (2.00-4.69) L/min/s, p ≤ 0.0001]. A VFPS threshold of 5.8 L/min/s predicted a PCWP ≥ 18 mm Hg with a sensitivity of 87% and specificity of 95% (AUC 0.95). Ventricular filling phase slope of the HVAD flow waveform is a novel noninvasive parameter that correlates with PCWP and can discriminate elevated versus normal or low PCWP. Automated reporting of this parameter may help clinical assessment and management of patients supported by an HVAD and may serve as the basis of a smart LVAD pump that can adapt in response to changes in a patient's physiology.
منابع مشابه
Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملLeft Atrial Pressure Monitoring With an Implantable Wireless Pressure Sensor After Implantation of a Left Ventricular Assist Device
After implantation of a continuous-flow left ventricular assist device (LVAD), left atrial pressure (LAP) monitoring allows for the precise management of intravascular volume, inotropic therapy, and pump speed. In this case series of 4 LVAD recipients, we report the first clinical use of this wireless pressure sensor for the long-term monitoring of LAP during LVAD support. A wireless microelect...
متن کاملHemodynamic Ramp Tests in Patients With Left Ventricular Assist Devices.
OBJECTIVES This study tested whether combined invasive hemodynamic and echocardiographic ramp tests can help optimize patient management. BACKGROUND Guidelines for optimizing speed and medications in continuous flow ventricular assist device (cfLVAD) patients are mainly based on expert opinion. METHODS Thirty-five cfLVAD patients (21 HeartMate II [Thoratec, Pleasanton, California] and 14 HV...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ASAIO journal
دوره 64 1 شماره
صفحات -
تاریخ انتشار 2018