Single-photon emission computed tomography appropriateness: does it matter for patient outcomes?

نویسندگان

  • Raymond J Gibbons
  • Todd D Miller
چکیده

I n this issue of Circulation, Doukky et al 1 report findings from a cohort of 1511 patients from 11 outpatient community based practices (20 primary care physicians and 2 cardiologists) in the Chicago metropolitan area. The patients underwent single-photon emission computed tomographic (SPECT) myocardial perfusion imaging and were then followed up for 27±10 months for major adverse cardiac events: death, death or myocardial infarction, and cardiac death or myocardial infarction. The SPECT studies were categorized on the basis of the 2009 appropriate use criteria (AUC) as appropriate, uncertain, or inappropriate. The investigators report that 823 patients (54.5%) underwent SPECT scans that were classified as appropriate or uncertain and 688 patients (45.5%) underwent SPECT scans that were classified as inappropriate. In those patients whose SPECT scans were appropriate or uncertain, abnormal scans were of significant value in predicting major adverse cardiac events with hazard ratios of 3.1 to 3.7 compared with normal scans. However, in those patients undergoing SPECT classified as inappropriate, abnormal SPECT scans did not achieve statistical significance in predicting major adverse cardiac events, although the hazard ratios ranged from 2.3 to 11.8. Regardless of the appropriate-ness of SPECT, the presence of ischemia on SPECT, reflected in the summed difference score (SDS), predicted subsequent coronary angiography and revascularization. As the investigators indicate, this is the first large study validating the prog-nostic implications of SPECT AUC, further supporting its clinical utility. In this editorial, we examine both the internal and external validity of this study to place it in context for evidence-based clinicians. Is the study internally valid? That is, do the data justify the conclusions? This study has a number of strengths, beginning with the size of the cohort and the several-year duration of follow up. Although follow-up was >99% complete, a number of patients were excluded (n=182) or lost to follow-up (n=14). To their credit, the authors systematically compare these patients with those patients with follow-up data. The differences were modest, suggesting that the exclusion of these patients did not bias the results. The SPECT studies were all acquired on a single dedicated cardiac SPECT camera and interpreted by a single expert nuclear cardiologist, eliminating the variability inherent in different equipment and different interpreters. The SPECT results were categorized into published groupings of the summed stress score and SDS, permitting comparison with extensive previous literature using the summed stress score and SDS. There were some potential methodological …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Sectional anatomy quiz

This mage based series comprises of a quiz pertaining to the identification of salient anatomical structures expected to be seen at a given level on the computed tomography (CT) followed by examples of multiple representative pathologies that can be seen at the same level in a routine clinical setting. It is expected that this will improve confidence of nuclear physicians in interpretation of t...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Neural Imaging Using Single-Photon Avalanche Diodes

Introduction: This paper analyses the ability of single-photon avalanche diodes (SPADs) for neural imaging. The current trend in the production of SPADs moves toward the minimumdark count rate (DCR) and maximum photon detection probability (PDP). Moreover, the jitter response which is the main measurement characteristic for the timing uncertainty is progressing. Methods: The neural imaging pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 128 15  شماره 

صفحات  -

تاریخ انتشار 2013