Second-generation everolimus-eluting stents versus first-generation sirolimus-eluting stents in acute myocardial infarction. 1-year results of the randomized XAMI (XienceV Stent vs. Cypher Stent in Primary PCI for Acute Myocardial Infarction) trial.

نویسندگان

  • Sjoerd H Hofma
  • Jan Brouwer
  • Matthijs A Velders
  • Arnoud W J van't Hof
  • Pieter C Smits
  • Michel Queré
  • Cornelis Jan de Vries
  • Adrianus J van Boven
چکیده

OBJECTIVES The goal of this study was to compare the efficacy and safety of second-generation everolimus-eluting stents (EES) with first-generation sirolimus-eluting stents (SES) in primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI). BACKGROUND Drug-eluting stents (DES) in AMI are still feared for possible late and very late stent thrombosis (ST). Newer-generation DES, with more hemocompatible polymers and improved healing, may show promise regarding increased efficacy of DES with improved safety. However, no randomized trials in AMI are available. METHODS A total of 625 patients with AMI were randomized (2:1) to receive EES or SES in the XAMI (XienceV Stent vs Cypher Stent in Primary PCI for Acute Myocardial Infarction) trial. Primary endpoint was major adverse cardiac events (MACE) at 1 year consisting of cardiac death, nonfatal AMI, or any target vessel revascularization. The study was powered for noninferiority of EES. Secondary endpoints comprised ST rates and MACE rate up to 3 years. RESULTS The MACE rate was 4.0% for EES and 7.7% for SES; the absolute difference was -3.7% (95% confidence interval: -8.28 to -0.03; p = 0.048) and relative risk was 0.52 (95% confidence interval: 0.27 to 1.00). One-year cardiac mortality was low at 1.5% for EES versus 2.7% for SES (p = 0.36), and 1-year incidence of definite and/or probable ST was 1.2% for EES versus 2.7% for SES (p = 0.21). CONCLUSIONS In this all-comer, randomized, multicenter AMI trial, second-generation EES was noninferior to SES, and superiority for MACE was suggested. ST rate in EES at 1-year was low, but long-term follow-up and larger studies will have to show whether very late ST rates will also be improved in newer DES. (XienceV Stent vs Cypher Stent in Primary PCI for Acute Myocardial Infarction [XAMI]; NTR1123).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-Year Results of an Open-Label Randomized Comparison of Everolimus-Eluting Stents and Sirolimus-Eluting Stents

BACKGROUND Second generation drug-eluting stents were developed to improve the safety and efficacy of first generation stents. So far, limited long term randomized data exist comparing the second generation everolimus-eluting stents (EES) with first generation sirolimus-eluting stents (SES). METHODS A prospective, open-label, randomized, single center trial comparing EES and SES in all-comer ...

متن کامل

Three-year follow-up of patients with bifurcation lesions treated with sirolimus- or everolimus-eluting stents: SEAside and CORpal cooperative study.

INTRODUCTION AND OBJECTIVES To compare the 3-year incidence of major events in patients with bifurcation lesions treated with provisional sirolimus-eluting stents vs everolimus-eluting stents. METHODS A pooled analysis of 2 prospective randomized trials with similar methodology (SEAside and CORpal) was performed. In these trials, 443 patients with bifurcation lesions were randomly assigned to...

متن کامل

Randomized trial of Sirolimus-Eluting Stent Versus Bare-Metal Stent in Acute Myocardial Infarction (SESAMI).

OBJECTIVES To confirm whether sirolimus-eluting stents (SES) safely reduce the incidence of restenosis in patients with ST-segment elevation acute myocardial infarction compared with bare-metal stents (BMS). BACKGROUND In the setting of primary angioplasty, stent restenosis occurs in up to 27% of patients. The introduction of drug-eluting stents has drastically reduced the incidence of resten...

متن کامل

Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.

BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...

متن کامل

Sirolimus-eluting versus uncoated stents in acute myocardial infarction.

BACKGROUND Sirolimus-eluting stents reduce rates of restenosis and reintervention, as compared with uncoated stents. Data are limited regarding the safety and efficacy of such stents in primary percutaneous coronary intervention (PCI) for acute myocardial infarction with ST-segment elevation. METHODS We performed a single-blind, multicenter, prospectively randomized trial to compare sirolimus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 60 5  شماره 

صفحات  -

تاریخ انتشار 2012