Mechanical impedance of the lung periphery.

نویسندگان

  • Z Hantos
  • F Peták
  • A Adamicza
  • T Asztalos
  • J Tolnai
  • J J Fredberg
چکیده

The mechanics of the regional airways and tissues was studied in isolated dog lobes by means of a modified wave-tube technique. Small-amplitude pseudorandom forced oscillations between 0.1 and 48 Hz were applied through catheters wedged in 2-mm-diameter bronchi in three regions of each lobe at translobar pressures (PL) of 10, 7, 5, 3, 2, and 1 cmH2O. The measured regional input impedances were fitted by a model containing the resistance (R1) and inertance (I) of the regular (segmental) airways, the resistance of the collateral channels (R2), and the damping (G) and elastance (H) of the local tissues. This model gave far better fits to the data on impedance of the lung periphery than when G and H were replaced by a single tissue compliance, which explains why interruption of segmental flow did not lead to monoexponential pressure decay in previous studies. The interlobar and intralobar variances of the parameters were equally significant, and poor correlations were found between the airway parameters R1 and R2 and between any airway and tissue parameter (e.g., R1 and H). R2 was on average approximately 10 times higher than R1, although the R2-to-R1 ratios and their dependencies on PL were regionally highly variable. However, for the total of 33 regions studied, the PL dependence was the same for R1 and R2, which may reflect similar morphological structures for the regular and collateral airways. The dependencies of G and H on PL showed high interregional variations; generally, however, they assumed their minima at medium PL values (approximately 5 cmH2O).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oscillation mechanics of the human lung periphery in asthma.

To more precisely measure the mechanical properties of the lung periphery in asthma, we have developed a forced oscillation technique that applies a broad-band flow signal through a wedged bronchoscope. We interpreted the data from four healthy and eight mildly asthmatic subjects in terms of an anatomically accurate computer model of the wedged segment. There was substantial overlap in impedanc...

متن کامل

Assessment of regional ventilation in acute respiratory distress syndrome by electrical impedance tomography.

Mechanical ventilation in acute respiratory distress syndrome (ARDS) incurs a risk of ventilator-associated lung injury (VALI) from inhomogeneous conditions and different properties of dependent and non-dependent lung regions at risk of atelectasis and overdistension, respectively. Electrical impedance tomography (EIT) offers regional ventilation assessment to optimise treatment with mechanical...

متن کامل

Measurement of lung function using Electrical Impedance Tomography (EIT) during mechanical ventilation

The consistency of regional lung density measurements as estimated by Electrical Impedance Tomography (EIT), in eleven patients supported by a mechanical ventilator, was validated to verify the feasibility of its use in intensive care medicine. There were significant differences in regional lung densities between the normal lung and diseased lungs associated with pneumonia, atelectasis and pleu...

متن کامل

Thermo-Electro Mechanical Impedance based Structural Health Monitoring: Euler- Bernoulli Beam Modeling

In recent years, impedance measurement method by piezoelectric (PZT) wafer activesensor (PWAS) has been widely adopted for non-destructive evaluation (NDE). In this method, theelectrical impedance of a bonded PWAS is used to detect a structural defect. The electro-mechanicalcoupling of PZT materials constructs the original principle of this method. Accordingly, the electricalimpedance of PWAS c...

متن کامل

Electrical impedance tomography: so close to touching the holy grail

Electrical impedance tomography is a new technology giving us lung imaging that may allow lung function to be monitored at the bedside. Several applications have been studied to guide mechanical ventilation at the bedside with electrical impedance tomography. Positive end-expiratory pressure trials guided by electrical impedance tomography are relevant in terms of recruited volume or homogeneit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 1997