Technetium-99 m in the diagnosis of thyrotoxicosis.
نویسندگان
چکیده
The thyroid uptake at 20 minutes of intravenously administered Technetium-99(m) ((99m)Tc) was measured in 117 patients with a standard scintillation counter. Patients were divided into three groups on the basis of clinical assessment, four-hour (131)I uptake, triiodothyronine (T-3) resin uptake, and protein-bound iodine measurements.In 31 patients with no evidence of thyroid disease the mean (99m) Tc uptake was 1.8% +/-S.D. 1.1%. In 32 patients with thyroid enlargement who were euthyroid the mean uptake was 2.5% +/-S.D. 2.2%. In 54 thyrotoxic patients the mean uptake was 17.7% with a range of 4.1 to 44%, all cases having an uptake above the upper limit of normal (4.0%). These results agree closely with reported uptake studies using scanning techniques. In seven patients the extrathyroidal neck activity was measured by using a scanner, and the mean was 6.3% of the extrathyroidal total body radioactivity comparing favourably with an assumed 6% used in our calculations.We have shown that the measurement of the thyroid uptake of (99m)Tc with a scintillation counter is of value, and that it is not necessary to use scanning techniques in the diagnosis of thyrotoxicosis. Advantages of (99m) Tc are minimal radiation, reduction in patient and laboratory time, and low cost.
منابع مشابه
Cut off value of technetium uptake in the differential diagnosis of Graves, disease and subacute thyroiditis
Objective(s):The aim of this study was to determine whether technetium (99mTc) uptake is a relevant method for the differential diagnosis of Graves disease and subacute thyroiditis and calculate its cutoff value in case of its relevancy. Methods: A total of 69 patients, who were followed up (>3 months) in our hospital for thyrotoxi...
متن کاملAssessment of molybdenum breakthrough levels in molybdenum-99/technetium-99m generators: One year experience at NIMRA Jamshoro Pakistan
Background: Technetium-99m radioisotope is the backbone of any nuclear medicine institute. This radioisotope is acquired by the elution of Molybdenum-99/Technetium-99m generator which emits 141 keV gamma ray and having 6.04 hour half-life. Occasionally the contents of Molybdenum-99 may mix up with elute, which may affect image quality and patients may receive higher doses than recommended. This...
متن کاملEffect of Thyrotoxicosis on Gene Expression of Hydrogen Sulfide-producing Enzymes in Epididymal Adipose Tissue of Male Rats
Introduction: Thyroid hormones are involved in the regulation of hydrogen sulfide (H2S) biosynthesis. The aim of this study is to determine effects of thyrotoxicosis on H2S levels and mRNA expression of cystathionine-β-synthase (CBS), cystathionine-γ-lyase (CSE) and 3-mercaptopyruvate sulfurtransferase (3-MST) in the adipose tissue of rat. Materials and Methods: Male rats were divided into the ...
متن کاملLingual dyskinesia in hyperthyroidism.
Asirvatham AR, et al. BMJ Case Rep 2017. doi:10.1136/bcr-2017-223226 Description A 28-year-old female presented to the hospital with a 3-month history of palpitation, weight loss and neck swelling. On examination, she had diffuse soft goitre, warm extremities and fine tremors of hands. In addition, she had an irregular jerky lingual and lip movements suggestive of dyskinesia (see online supplem...
متن کاملA New99m Tc Generator using Cerium (IV) Oxide as an Adsorbent for99 Mo
In this research, a new technetium-99m generator has been developed with addition of Cerium oxide to alumina column. The adsorption behaviors of 99Mo in the form of molybdate and 99mTc in the form of pertechnetate on CeO2/Al2O3 was investigated and showed that the adsorption capacity of molybdate on this generator is higher than usual generator using Al2O3. Ceric ions were selected as an addit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British medical journal
دوره 4 5834 شماره
صفحات -
تاریخ انتشار 1972