Visual Measurement of Suture Strain for Robotic Surgery

نویسندگان

  • John Martell
  • Thomas W. Elmer
  • Nachappa Gopalsami
  • Young Soo Park
چکیده

Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leyla loop: a time-saving suture technique for robotic atrial closure.

The longer durations of cardiopulmonary bypass and aortic cross-clamp times remain the disadvantages of robotic or minimally invasive cardiac surgery. For this reason, every small contribution to speeding up these procedures is of the utmost importance. Here, we present a practical, easy and time-saving suture technique for atrial closure. It consists of a hand-made loop at one end of the sutur...

متن کامل

The capability of haptic feedback as additional sensory quality for robotic heart surgery

The implementation of telemanipulator systems into cardiac surgery enabled the heart surgeon to perform sophisticated minimally invasive and endoscopic procedures with high precision under stereoscopic view. At present, the commercially available robotic surgical systems do not provide force feedback for the operating surgeon. The lack of tactile feedback may cause damage of tissue and bending ...

متن کامل

Effect of Residents' Previous Laparoscopic Surgery Experience on Initial Robotic Suturing Experience

Objective. To assess the impact of gynecology residents' previous laparoscopic experience on the learning curve of robotic suturing techniques and the value of initial structured teaching in dry lab prior to surgery. Methods. Thirteen gynecology residents with no previous robotic surgery experience were divided into Group 1, consisting of residents with 2 or fewer laparoscopic experiences, and ...

متن کامل

Comparison of Three Different Methods of Skin Closure in Anterior Midline Incisions of the Knee

Background:  Few clinical trials have studied the functional and cosmetic outcomes of different closure tech- niques of surgical incisions. Skin wound and incision closure methods may influence the healing process and cos- metic outcome. The present study aims at comparing three different suture techniques of skin closure. Methods: In a clinical trial, sixty patients with anterior cruciate liga...

متن کامل

Haptic Feedback in a Telepresence System for Endoscopic Heart Surgery

The implementation of telemanipulator systems for cardiac surgery enabled heart surgeons to perform delicate minimally invasive procedures with high precision under stereoscopic view. At present, commercially available systems do not provide force-feedback or Cartesian control for the operating surgeon. The lack of haptic feedback may cause damage to tissue and can cause breaks of suture materi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011