CD3+ lymphocytosis in the peri-implant membrane of 222 loosened joint endoprostheses depends on the tribological pairing

نویسندگان

  • Felix Hopf
  • Peter Thomas
  • Stefan Sesselmann
  • Marc N Thomsen
  • Maximilian Hopf
  • Johannes Hopf
  • Manfred G Krukemeyer
  • Herbert Resch
  • Veit Krenn
چکیده

Background and purpose - The most frequent cause of arthroplasty failure is aseptic loosening-often induced by particles. Abrasion material triggers inflammatory reactions with lymphocytic infiltration and the formation of synovial-like interface membranes (SLIM) in the bone-implant interface. We analyzed CD3 quantities in SLIM depending on articulating materials and possible influences of proven material allergies on CD3 quantities. Patients and methods - 222 SLIM probes were obtained from revision surgeries of loosened hip and knee arthroplasties. SLIM cases were categorized according to the SLIM-consensus classification and to the particle algorithm. The CD3 quantities were analyzed immunohistochemically, quantified, and correlated to the particle types. Results - Metal-metal pairings showed the highest CD3 quantities (mean 1,367 counted cells). CD3 quantities of metal-polyethylene (mean 243), ceramic-polyethylene (mean 182), and ceramic-ceramic pairings (mean 124) were significantly smaller. Patients with contact allergy to implant materials had high but not statistically significantly higher CD3 quantities than patients without allergies. For objective assessment of the CD3 response as result of a pronounced inflammatory reaction with high lymphocytosis (adverse reaction), a defined CD3 quantity per high power field was established, the "CD3 focus score" (447 cells/0.3 mm2, sensitivity 0.92; specificity 0.90; positive predictive value 0.71; negative predictive value 0.98). Interpretation - The high CD3 quantities for metal-metal pairings may be interpreted as substrate for previously described adverse reactions that cause severe peri-implant tissue destruction and SLIM formation. It remains unclear whether the low CD3 quantities with only slight differences in the various non-metal-metal pairings and documented contact allergies to implant materials have a direct pathogenetic relevance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Maintenance of Dental Implants: A Review

  Objective: Successful bonding of a dental implant to bone, which was referred to as osseointegration by Branemark has been well documented. However, long-term prognosis of an implant depends on adequate maintenance and long-term care. An effective maintenance program is required to preserve the health of peri-implant tissues. Several techniques have been suggested for this purpose but it is n...

متن کامل

Receptor Activator of Nuclear Factor Kappa B Ligand (RANKL) Levels in Peri-Implant Crevicular Fluid

Background: Receptor activator of nuclear factor kappa B ligand (RANKL) is one of the key cytokines in the induction of osteoclastogenesis both in vitro and in vivo.Several reports indicated the presence of sRANKL in gingival crevicular fluid of patients with periodontal diseases. Objective: To determine the presence of RANKL in peri-implant crevicular fluid samples of implants with peri-implan...

متن کامل

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

Wear Testing of Total Hip Joints According to Iso and Development of a New Hip Joint Simulator According to Iso

INTRODUCTION The development of new, highly sophisticated materials for the articulating surfaces of total hip endoprostheses has led to an increasing demand for testing and verification. This includes tests and research regarding bio-compatibility, static load bearing capacity of the prostheses as well as tribological investigations. Since it has been found that wear debris play a dominant rol...

متن کامل

تعیین توزیع تنش استخوان اطراف ایمپلنت‌های فک پایین در طرح‎های مختلف پروتز به هنگام Mandibular- Flexure

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 88  شماره 

صفحات  -

تاریخ انتشار 2017