Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients.

نویسندگان

  • R J Boots
  • S Howe
  • N George
  • F M Harris
  • J Faoagali
چکیده

OBJECTIVE To compare the degree of bacterial circuit colonization, frequency of ventilator-associated pneumonia (VAP), character of respiratory secretions, rewarming of hypothermic patients, disposable costs, and air flow resistance in intensive care patients ventilated using either a heat and moisture exchanger (HME) or hot water (HW) humidifier circuit. DESIGN A prospective, randomized blinded trial of patients in the intensive care unit undergoing mechanical ventilation. SETTING A metropolitan teaching hospital. PATIENTS One hundred sixteen patients undergoing mechanical ventilation for a minimum period of 48 hrs were enrolled. INTERVENTIONS Patients were randomized to three ventilation groups using a) an HW circuit with a 2-day circuit change (n = 41); or b) a bacterial-viral filtering HME in the circuit, with either a 2-day (n = 42); or c) a 4-day circuit change (n = 33). MEASUREMENTS AND MAIN RESULTS Circuit colonization was assessed using quantitative culture of washings taken from the circuit tubing and semiquantitative culture of swabs from the Y connectors. Sixty-seven percent of HW circuits became contaminated compared with 12% in the two HME groups (p < .0001). Median colony counts were lower in the HME groups (p < .0001). If circuits at first circuit change were contaminated in the HW group, 89% of subsequent circuit changes became contaminated compared with 0% and 25% for the 2- and 4-day HME groups, respectively. The frequency of VAP, the time to resolution of admission hypothermia, and the volume and fluidity of secretions were similar for all groups. The resistance of the HME after 24 hrs of use was < 0.025 cm H2O/L at gas flows of 40 L/min. HME use resulted in a cost reduction of $1.48 (Australian)/day. CONCLUSIONS Circuits with a bacterial-viral filtering HME are less readily colonized by bacteria. Contamination is a random event. Humidification technique has no influence on the frequency rate of VAP, the effectiveness of rewarming, nor the character of the respiratory secretions. Breathing resistance is generally low and disposable costs are reduced when an HME is used.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Humidification for Patients with Artificial Airways

Introduction Normal Mechanisms of Heat and Moisture Exchange in the Respiratory Tract High-Flow Humidifiers Pass-over Humidifiers Wick Humidifiers Bubble Humidifiers Artificial Noses Moisture Output Resistance Dead Space Additives Cost Choosing an Artificial Nose Active Hygroscopic Heat and Moisture Exchangers HME-Booster Use of Humidification Devices During Mechanical Ventilation Use of Heated...

متن کامل

Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.

INTRODUCTION When endotracheal intubation is required during ventilatory support, the physiologic mechanisms of heating and humidifying the inspired air related to the upper airways are bypassed. The task of conditioning the air can be partially accomplished by heat-and-moisture exchangers (HMEs). OBJECTIVES To evaluate and compare with respect to imposed resistance, different types/models of...

متن کامل

Measurement of tracheal temperature is not a reliable index of total respiratory heat loss in mechanically ventilated patients

BACKGROUND Minimizing total respiratory heat loss is an important goal during mechanical ventilation. The aim of the present study was to evaluate whether changes in tracheal temperature (a clinical parameter that is easy to measure) are reliable indices of total respiratory heat loss in mechanically ventilated patients. METHOD Total respiratory heat loss was measured, with three different me...

متن کامل

Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.

OBJECTIVE During invasive mechanical ventilation, inspired gases must be humidified. We previously showed that high ambient temperature greatly impaired the hygrometric performance of heated wire-heated humidifiers. The aim of this bench and clinical study was to assess the humidification performance of passive and active heat and moisture exchangers (HMEs) and the impact of ambient temperature...

متن کامل

Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia.

OBJECTIVE Many heat and moisture exchangers with filter (HMEF) have been developed. In-house data from companies provide some information about their performances; unfortunately, to our knowledge, no comparative evaluation in clinical conditions has been undertaken of these newer products. The aim of this study was to compare the efficiency of two HMEFs, one hydrophobic and one hygroscopic, on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical care medicine

دوره 25 10  شماره 

صفحات  -

تاریخ انتشار 1997