Femoral anteversion in the hip: comparison of measurement by computed tomography, magnetic resonance imaging, and physical examination.
نویسندگان
چکیده
PURPOSE The purpose of this study was to evaluate the correlation between computed tomography (CT) and magnetic resonance imaging (MRI) measurements of femoral anteversion, as well as the relation of anteversion with physical examination and radiographic findings. METHODS Preoperative CT and MRI measurements of anteversion along with clinical examination were performed on 129 consecutive hips before hip arthroscopy for nonarthritic hip injuries. All anteversion measurements were performed by 2 musculoskeletal radiologists. The radiographic findings and physical examination findings were analyzed for statistically significant correlations. For statistical analysis purposes, the patients were divided into 3 groups according to the mean CT anteversion measurement: group I (low), less than 10°; group II (medium), 10° to 22°; and group III (high), greater than 22°. RESULTS High interobserver correlation was found for femoral anteversion measurement by CT and MRI (r = 0.95 and r = 0.86, respectively; P < .0001 for both). CT and MRI measurements showed high correlation with each other (r = 0.80, P < .0001). However, in 96% of the cases, the CT measurement was larger, with a mean difference of 8.9° (range, -37° to 1.5°). A significant correlation coefficient was found between internal rotation and anteversion angles as measured by CT (r = 0.36, P < .0001). However, no correlation was found with other hip movement measurements. Abnormal femoral acetabular bony architecture of the hip was found in 64% of the patients; isolated cam impingement was more prevalent in group I, whereas isolated pincer impingement was more prevalent in group III (P = .01). CONCLUSIONS Although high correlation was found between anteversion angle measurements by CT and MRI, significant discrepancies in the absolute anteversion number between the 2 techniques suggest that they may not be interchangeable. Furthermore, CT was found to have higher interobserver reliability than MRI. There was a significant correlation between CT and examination of internal rotation of the hip. Clinically, the findings of the study show that the diagnosis of excessive femoral anteversion or retroversion should have different thresholds according to MRI and CT measurements; moreover, the diagnosis should not rely exclusively on either examination or radiologic criteria. LEVEL OF EVIDENCE Level III, retrospective comparative study.
منابع مشابه
Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review
Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...
متن کاملMeasurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملValidity and reliability of radiological methods to assess proximal hip geometry in children with cerebral palsy: a systematic review.
AIM The aim of this systematic review was to assess the current validity and reliability of radiological methods used to measure proximal hip geometry in children with cerebral palsy. METHOD A search was conducted using relevant keywords and inclusion/exclusion criteria of the MEDLINE, CINALH Plus, Embase, Web of Science, Academic Search Premier, The Cochrane Library, and PsychINFO databases....
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2012