device for sutureless aorta-saphenous vein anastomosis.
نویسنده
چکیده
منابع مشابه
Surgical repair of a celiac artery aneurysm using a sutureless proximal anastomosis device
Some celiac artery aneurysms are not suitable for endovascular therapy. We describe the case of a 63-year-old man with a celiac trunk aneurysm extending to the hepatosplenic bifurcation. The aneurysm was resected and oversewn at the origin from the abdominal aorta. A saphenous vein bypass from the supraceliac aorta to the celiac artery bifurcation was performed using a sutureless anastomotic de...
متن کاملA case of ostial stenosis with the PAS-Port proximal anastomosis system in off-pump coronary artery bypass grafting.
The use of an automatic aortic connector device for proximal saphenous vein graft anastomoses eliminates the need for aortic clamping during off-pump coronary artery bypass grafting and may reduce the incidence of stroke in the elderly and in patients with severe aortic atherosclerosis. The PAS-Port proximal anastomotic system is a recently developed sutureless automatic saphenous vein graft an...
متن کاملInitial experience with proximal anastomoses performed with a mechanical connector.
BACKGROUND The Symmetry Bypass System Aortic Connector (St Jude Medical, Inc) is a novel device for the construction of sutureless proximal anastomoses. The connector allows attachment of saphenous vein grafts to the aorta without requiring aortic clamping. We report our initial clinical experience with this device. METHODS In a 2-month period from May to July 2001, a total of 139 consecutive...
متن کاملHuge aortic pseudoaneurysm arising from the aorta-saphenous vein graft anastomosis after coronary artery bypass grafting.
Pseudoaneurysm of the aortic root is a rare condition and potentially fatal if not treated. It may occur in different etiologies. In this case, we aim to show an aortic pseudoaneurysm arising from the aorta-saphenous vein graft anastomosis.
متن کاملNew device for saphenous vein-to-aorta proximal anastomosis without side-clamping
BACKGROUND Side clamping to perform saphenous vein-to-aorta proximal anastomosis is a well known cause of cerebral embolization during coronary bypass surgery. Automatic and manual devices have been introduced to avoid aortic clamping and facilitate proximal anastomosis but the manual ones only allow the traditional hand-sewing running suture. Nevertheless, they are not easy to use and very exp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008