Ultrahigh-resolution optical coherence tomography.

نویسنده

  • Wolfgang Drexler
چکیده

In the past two decades, optical coherence tomography (OCT) has been established as an adjunct diagnostic technique for noninvasive, high-resolution, cross-sectional imaging in a variety of medical fields. The rapid development of ultrabroad bandwidth light sources has recently enabled a significant improvement in OCT imaging resolution, demonstrating the potential of OCT to accomplish its original goal of performing noninvasive optical biopsies, i.e., the in vivo visualization of microstructural morphology in situ, which had previously only been possible with histopathology. In addition, these novel light sources might also enable the use of spectroscopic OCT, an extension of ultrahigh-resolution OCT, for enhancing image contrast as well as detecting spatially resolved functional, biochemical tissue information. State-of-the-art-light sources that now permit ultrahigh-resolution OCT covering the whole wavelength region from 500 to 1600 nm are reviewed and fundamental limitations of OCT image resolution are discussed. Ex vivo ultrahigh-resolution OCT tomograms are compared with histological results; first clinical in vivo ultrahigh-resolution OCT and preliminary spectroscopic OCT results are presented and their impact for future clinical and research applications is discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrahigh resolution optical coherence tomography using a superluminescent light source.

A superluminescent Ti:Al2O(3) crystal is demonstrated as a light source for ultrahigh resolution optical coherence tomography (OCT). Single spatial mode, fiber coupled output powers of ~40 microW can be generated with 138 nm bandwidth using a 5 W frequency doubled, diode pumped laser, pumping a thin Ti:Al2O(3) crystal. Ultrahigh resolution OCT imaging is demonstrated with 2.2 microm axial resol...

متن کامل

Intact retinal tissue and retinal pigment epithelium identified within a coloboma by high-speed, ultrahigh-resolution optical coherence tomography.

PURPOSE The purpose of this study was to report on a posterior segment coloboma manifesting unusual morphology as determined by high-speed, ultrahigh-resolution optical coherence tomography imaging. METHODS A 47-year-old woman with bilateral colobomas was evaluated by fundus examination and high-speed, ultrahigh-resolution optical coherence tomography imaging. RESULTS Imaging with high-spee...

متن کامل

Ultrahigh-resolution optical coherence tomography with a diode-pumped broadband Cr(3+):LiCAF laser.

Ultrahigh resolution optical coherence tomography (OCT) is performed with a broadband, Kerr-lens mode-locked, diode-pumped Cr(3+):LiCAF laser. The laser source has a bandwidth of 89 nm with an output power of 37 mW. OCT imaging is demonstrated with 4.5 microm axial resolution in air or 3.4 microm in tissue. In vivo imaging of the human retina is demonstrated. Ultrahigh resolution OCT images fro...

متن کامل

Ultrahigh-resolution full-field optical coherence tomography using spatial coherence gating and quasi-monochromatic illumination.

We developed an ultrahigh-resolution full-field optical coherence tomography (FF-OCT) microscope that is based on the spatial, rather than the temporal, coherence gating. The microscope is capable of observing three-dimensional microbiological structures as small as 0.4 μm × 0.4 μm × 1.0 μm (xyz) using quasi-monochromatic light and a liquid crystal retarder. Unlike traditional FF-OCT systems, t...

متن کامل

Optimal wavelength for ultrahigh-resolution optical coherence tomography.

The influence of depth dependent dispersion by the main component of biological tissues, water, on the resolution of OCT was studied. Investigations showed that it was possible to eliminate the influence of depth dependent dispersion by water in tissue by choosing a light source with a center wavelength near 1.0 microm. Ultrahigh resolution ophthalmic imaging was performed at this wavelength ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2004