Temporal decline in defibrillation thresholds with an active pectoral lead system.
نویسندگان
چکیده
OBJECTIVES The objective of this study was to characterize temporal changes in defibrillation thresholds (DFTs) after implantation with an active pectoral, dual-coil transvenous lead system. BACKGROUND Ventricular DFTs rise over time when monophasic waveforms are used with non-thoracotomy lead systems. This effect is attenuated when biphasic waveforms are used with transvenous lead systems; however, significant increases in DFT still occur in a minority of patients. The long-term stability of DFTs with contemporary active pectoral lead systems is unknown. METHODS This study was a prospective assessment of temporal changes in DFT using a uniform testing algorithm, shock polarity and dual-coil active pectoral lead system. Thresholds were measured at implantation, before discharge and at long-term follow-up (70 +/- 40 weeks) in 50 patients. RESULTS The DFTs were 9.2 +/- 5.4 J at implantation, 8.3 +/- 5.8 J before discharge and 6.9 +/- 3.6 J at long-term follow-up (p < 0.01 by analysis of variance; p < 0.05 for long-term follow-up vs. at implantation or before discharge). The effect was most marked in a prespecified subgroup with high implant DFTs (> or =15 J). No patient developed an inadequate safety margin (< 9 J) during follow-up. CONCLUSIONS The DFTs declined significantly after implantation with an active pectoral, dual-coil transvenous lead system, and no clinically significant increases in DFT were observed. Therefore, routine defibrillation testing may not be required during the first two years after implantation with this lead system, in the absence of a change in the cardiac substrate or treatment with antiarrhythmic drugs.
منابع مشابه
Comparison of single- and dual-coil active pectoral defibrillation lead systems.
OBJECTIVES The purpose of this study was to compare defibrillation thresholds with lead systems consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Lead systems that include an active pectoral pulse generator reduce defibrillation thresholds and permit transvenous defibrillation in nearly all patients. A further improvement in defibrillation...
متن کاملAtrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.
OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...
متن کاملA multifilamented electrode in the middle cardiac vein reduces energy requirements for defibrillation in the pig.
OBJECTIVE To compare the defibrillation efficacy of a novel lead system placed in the middle cardiac vein with a conventional non-thoracotomy lead system. METHODS In eight pigs (weighing 35-71 kg), an electrode was advanced transvenously to the right ventricular apex (RV), with the proximal electrode in the superior caval vein (SCV). Middle cardiac vein (MCV) angiography was used to delineate...
متن کاملAxillary or a Pectoral Thoracic Electrode Location
Background. A significant proportion of patients receiving endocardial defibrillation lead systems must accept either high defibrillation thresholds (DFTs) with lower safety margins or lead implantation by thoracotomy. We examined the feasibility of achieving universal application of endocardial leads and lower defibrillation energy requirements by optimizing the lead system location in conjunc...
متن کاملElectrode system influence on biphasic waveform defibrillation efficacy in humans.
BACKGROUND Several clinical studies have demonstrated a general superiority of biphasic waveform defibrillation compared with monophasic waveform defibrillation using epicardial lead systems. To test the breadth of utility of biphasic waveforms in humans, a prospective, randomized evaluation of defibrillation efficacy of monophasic and single capacitor biphasic waveform pulses was performed for...