A sequential injection chromatography (SIC) constructed from a short monolithic column and a microfluidic polymer chip with an embedded Cl ion-selective electrode (Cl-ISE) as a detector was developed for simultaneous determination of common inorganic anions. Under the optimal flow conditions of the SIC system, the determination range for Cl, NO2 , Br, NO3 ions was as follows: For Cl ion in a concentration range from 1.0 x 10 to 5.0 x 10 mol dm, for NO2 ion in the concentration range from 1.0 x 10 to 5.0 x 10 mol dm, for Br ion in the concentration range from 1.0 x 10 to 5.0 x 10 mol dm, and for NO3 ion in the concentration range from 3.0 x 10 to 1.0 x 10 mol dm, respectively. Limit of detection, defined as S/N=3, was ca. 3.0 x 10 mol dm for Cl, NO2 , Br, NO3 ions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

Sequential injection analysis of thiocyanate ions using a microfluidic polymer chip with an embedded ion-selective electrode.

A sequential injection analysis (SIA) system for the determination of SCN(-) ion using a microfluidic polymer chip with an embedded SCN(-) ion-selective electrode (SCN(-)-ISE) as a detector was developed. Under the optimal flow conditions of the SIA system, the SCN(-)-ISE showed a good linear relationship between peak heights and logarithmic concentrations of SCN(-) ion with a Nernstian slope o...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

متن کامل

Determination of inorganic anions in environmental waters with a hydroxide-selective column.

US Environmental Protection Agency Method 300.0 specifies the use of an IonPac AS4A anion-exchange column with a carbonate-hydrogencarbonate eluent and suppressed conductivity detection for the determination of inorganic anions in environmental waters by ion chromatography. Hydroxide eluents have not typically been used for the routine analysis of common inorganic anions due to the lack of an a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013