Temperature- and pH-sensitive wearable materials for monitoring foot ulcers
نویسندگان
چکیده
Foot ulcers account for 15% of comorbidities associated with diabetes. Presently, no device allows the status of foot ulcers to be continuously monitored when patients are not hospitalized. In this study, we describe a temperature and a pH sensor capable of monitoring diabetic foot and venous leg ulcers developed in the frame of the seventh framework program European Union project SWAN-iCare (smart wearable and autonomous negative pressure device for wound monitoring and therapy). Temperature is measured by exploiting the variations in the electrical resistance of a nanocomposite consisting of multiwalled carbon nanotubes and poly(styrene-b-(ethylene-co-butylene)-b-styrene). The pH sensor used a graphene oxide (GO) layer that changes its electrical potential when pH changes. The temperature sensor has a sensitivity of ~85 Ω/°C in the range 25°C-50°C and a high repeatability (maximum standard deviation of 0.1% over seven repeated measurements). For a GO concentration of 4 mg/mL, the pH sensor has a sensitivity of ~42 mV/pH and high linearity (R2=0.99).
منابع مشابه
Design and development of ShrewdShoe, a smart pressure sensitive wearable platform
This study introduces a wearable in-shoe system for real-time monitoring and measurement of the plantar pressure distribution of the foot using eleven sensing elements. The sensing elements utilized in ShrewdShoe have been designed in an innovative way, they are based on a barometric pressure sensor covered with a silicon coating. The presented sensing element has great linearity up to 300...
متن کاملThe use of multi-frequency impedimetry for the monitoring of chronic wounds: the BIPPED clinical study
The number of people developing type II diabetes is verging on epidemic proportions in some countries. Along with an aging population, the incidence of chronic diabetic foot ulcers and venous leg ulcers is increasing and threatens to pose a problem for healthcare systems. A smart, wearable autonomous wound therapy and monitoring device is the goal of the Swan-iCare project, which involves 9 con...
متن کاملDesign and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention
Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...
متن کاملPreventing diabetic foot ulcer recurrence in high-risk patients: use of temperature monitoring as a self-assessment tool.
OBJECTIVE The purpose of this study was to evaluate the effectiveness of a temperature monitoring instrument to reduce the incidence of foot ulcers in individuals with diabetes who have a high risk for lower extremity complications. RESEARCH DESIGN AND METHODS In this physician-blinded, randomized, 15-month, multicenter trial, 173 subjects with a previous history of diabetic foot ulceration w...
متن کاملSoft Contact-lens Sensor for Monitoring Tear Sugar as Novel Wearable Device of Body Sensor Network
A soft contact-lens amperometric glucose sensor as novel wearable device of body sensor network was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode, which was fabricated using “Soft-MEMS” techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -