Effect of intravenous versus epidural fentanyl on the minimum local analgesic concentration of epidural bupivacaine in labor.

نویسندگان

  • L S Polley
  • M O Columb
  • N N Naughton
  • D S Wagner
  • D M Dorantes
  • C J van de Ven
چکیده

BACKGROUND The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the relative local anesthetic sparing efficacies of intravenous and epidural fentanyl by comparison of their effects on the MLAC of bupivacaine. METHODS In this double-blind, randomized, prospective study, 84 parturients at < or = 7-cm cervical dilation who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 44) or bupivacaine with 3 microg/ml (60 microg) fentanyl (n = 40) was administered. The plain bupivacaine group then received 60 microg intravenous fentanyl. The bupivacaine-fentanyl group received intravenous saline. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min define as effective. RESULTS The MLAC of bupivacaine-intravenous fentanyl was 0.064% wt/vol (95% confidence interval, 0.049-0.080), and the MLAC of bupivacaine-epidural fentanyl was 0.034% wt/vol (95% confidence interval, 0.017-0.050). Epidural fentanyl significantly increased the analgesic potency of bupivacaine by a factor of 1.88 (95% confidence interval, 1.09-3.67) compared with intravenous fentanyl. The epidural fentanyl group demonstrated significantly higher dermatomal spread (P = 0.0064) and increased pruritus (P = 0. 01). CONCLUSIONS Epidural fentanyl significantly reduced the MLAC of bupivacaine when compared with intravenous fentanyl for the parturients in this study. The significantly enhanced local anesthetic sparing, dermatomal level, and pruritus with epidural fentanyl suggest a primarily spinal site of action.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EFFECTS OF EPIDURAL ANALGESI A WITH LOW-DOSE BUPIVACAINE AND FENTANYL ON THE PROGRESS OF LABOR AND MODE OF DELIVERY

Background and Objective: Epidural analgesia (EA) has been used to relieve labor pain in many obstetric units, yet controversy persists about its effect on progress and outcome in labor. The purpose of the current study was to evaluate the effect of EA on the rate of cervical dilation and myometrial contractility. Methods: In a 6-month period, 36 women who received standardized EA were mat...

متن کامل

Comparison of Epidural versus Entonox for Labor Analgesia in Nulliparous Women

 Introduction: The aim of this study is to compare the efficacy of epidural versus entonox methods for labor analgesia in nulliparous women.  Methods: This randomized controlled trial was performed on 84 nulliparous women with - pregnancy admitted to Imam Reza Hospital in 10 May 2010- 10 May 2011.  They were randomly divided into two groups 42 women inhaled entonox in active phase at the ...

متن کامل

Minimum local analgesic dose of intrathecal bupivacaine in labor and the effect of intrathecal fentanyl.

BACKGROUND Combining bupivacaine with fentanyl for intrathecal analgesia in labor is well recognized, but dosages commonly used are arbitrarily chosen and may be excessive. This study aimed to determine the median effective dose (ED50) of intrathecal bupivacaine, defined as the minimum local analgesic dose (MLAD), and then use this to assess the effect of different doses of fentanyl. METHODS ...

متن کامل

Levobupivacaine for epidural analgesia in labor: the sparing effect of epidural fentanyl.

Evidence suggests that levobupivacaine has similar pharmacodynamic properties to racemic bupivacaine. We sought to investigate whether this similarity extends to opioid sparing when levobupivacaine is used for epidural analgesia in laboring women by quantifying the effect of fentanyl on the minimum local analgesic concentration (MLAC) of levobupivacaine. One-hundred-six women requesting epidura...

متن کامل

[The efficacy and safety of continuous epidural analgesia versus intradural-epidural analgesia during labor].

OBJECTIVE To determine the efficacy and safety of intradural-epidural analgesia in comparison with continuous epidural analgesia during labor and childbirth. PATIENTS AND METHOD Forty-two women whose labor began spontaneously were enrolled and distributed randomly in two groups. The intradural-epidural analgesia group (IEA, n = 21) received 25 microgram of intradural fentanyl with 2.5 mg of i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2000