Using electrodiagnostic machine to study movement rhythm variation.

نویسندگان

  • Chuen-Der Kao
  • Jen-Tse Chen
  • Yi-Chung Lee
  • Din-E Shan
  • Yung-Yang Lin
  • Robert Chen
  • Petrina S T Chung
  • Zin-An Wu
  • Kwong-Kum Liao
چکیده

BACKGROUND Hand movement constitutes the most common daily activities in our life. Hand dexterity is often impaired in patients with neurological disease. We developed an adjunct method, based upon the electrodiagnostic software, for study of motor control and hand dexterity. METHODS Thirty-two normal subjects, 2 stroke patients and 2 Parkinson patients were included in the study. All of them were right-handed, and were asked to pace rhythmic finger tapping at a comfortable rate without cue or any external stimuli. A trigger kit was designed to transform the finger tapping. After using the triggering mode and adjusting the sweep speed, 2 tapping signals were simultaneously displayed on the screen. The first signal was the triggering potential, and the variation in timing of the second signal represented the variation in timing of the inter-response interval. Twenty sweeps were recorded, superimposed and measured on the screen. Movement rhythm variation (MRV) was defined as b/a x 100 (b = [maximal interval of finger tapping - minimal interval of finger tapping]; a = [maximal interval of finger tapping + minimal interval of finger tapping]/2). Each subject started with right hand and then left hand. RESULTS MRV measurement showed excellent intrarater (r = 0.97) and interrater (r = 0.97) reliability. In normal right-handed subjects, the MRV was better in right hand than in left hand (right 16.5 +/- 4.1% and left 21.0 +/- 7.6%; p < 0.05). The MRV improved in stroke patients along with the recovery and improved in Parkinson patients after levodopa treatment. CONCLUSIONS MRV was a good method to provide quantitative data for assessment of hand dexterity. Our study also showed the potential role of MRV in motor control study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heart Rate Variability Classification using Support Vector Machine and Genetic Algorithm

Background: Electrocardiogram (ECG) is defined as an electrical signal, which represents cardiac activity. Heart rate variability (HRV) as the variation of interval between two consecutive heartbeats represents the balance between the sympathetic and parasympathetic branches of the autonomic nervous system.Objective: In this study, we aimed to evaluate the efficiency of discrete wavelet transfo...

متن کامل

Techniques to Foster Drum Machine Expressivity

Electronic drum machines need algorithms to help them produce \expressivesounding" rhythmic phrases. In [Bilmes, 1992], I claim that three perceptually separate elements characterize percussive rhythm: metric content, tempo variation, and deviations (formerly called event-shifts). Herein, I demonstrate that algorithms based on this model may considerably facilitate reproduction of expressive rh...

متن کامل

A computer vision framework for finger-tapping evaluation in Parkinson's disease

OBJECTIVES The rapid finger-tapping test (RFT) is an important method for clinical evaluation of movement disorders, including Parkinson's disease (PD). In clinical practice, the naked-eye evaluation of RFT results in a coarse judgment of symptom scores. We introduce a novel computer-vision (CV) method for quantification of tapping symptoms through motion analysis of index-fingers. The method i...

متن کامل

Progression of Carpal Tunnel Syndrome According to Electrodiagnostic Testing in Nonoperatively Treated Patients

Background:  This study tested the null hypothesis that nonoperatively treated patients would not show disease progression of carpal tunnel syndrome (CTS) over time according to median nerve distal motor latency (DML) on two electrodiagnostic tests.   Methods:  This retrospective study analyzed sixty-two adult nonoperatively treated patients who were diagnosed with CTS confirmed by a minimum of...

متن کامل

The Effect of Bridge Orientation in Casting Machine on the Castability and Quality of Base Metal Castings

Introduction: The aim of this study was to evaluate the effect of bridge orientation in casting machine on castability and quality of base metal castings. Methods: Three groups of patterns with different direction and lengths in casting machine were casted and then studied qualitatively and quantitatively using mean and standard deviation in table of frequency. Results: Larger nodules and poros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Chinese Medical Association : JCMA

دوره 66 10  شماره 

صفحات  -

تاریخ انتشار 2003