High-resolution emboli detection and differentiation by characteristic postembolic spectral patterns.

نویسندگان

  • F Ries
  • K Tiemann
  • C Pohl
  • C Bauer
  • M Mundo
  • H Becher
چکیده

BACKGROUND AND PURPOSE High-intensity transient signals (HITS) detected by transcranial Doppler ultrasonography correspond to microemboli in intracranial arteries. The purpose of this study was to develop new diagnostic criteria for the differentiation of these microembolic signals from artifact, based on a high-resolution analysis of Doppler power spectra in an in vitro model. METHODS Two hundred seventy-six formed emboli, consisting of different biological and nonbiological materials and as air bubbles, were injected into a flow phantom with artificial blood vessels and perfused in a steady or a pulsatile way. Embolic passage was assessed with a modified 2.5-MHz pulsed Duplex machine and a commercial 2-MHz Doppler system. Embolic HITS were analyzed using internationally accepted criteria for the audiovisual characteristics of HITS. Doppler spectra changes associated with HITS were evaluated by means of a specially developed high-resolution analysis of Doppler raw data. RESULTS Seventy-seven percent of all embolic events could be identified using conventional audiovisual criteria for embolic HITS. Analysis of Doppler spectra showed that all injected emboli generated high-amplitude signals with a minimum of at least 3 dB above background level. In addition, using high-resolution processing, specific changes in Doppler spectral patterns could be identified after all embolic HITS caused by solid particles. These postembolic spectral patterns were always characterized by a Doppler frequency shift decreasing in time and resembling the letter lambda (lambda). Duration and appearance of the postembolic spectral patterns were mainly influenced by the size and velocity of the embolus. Similar phenomena could not be found in case of embolism by either small air bubbles or in case of provoked artifact registration. Using a commercial Doppler system specific, we documented postembolic spectral patterns in 47% of injected emboli. CONCLUSIONS In this study, highly specific changes in Doppler spectral patterns associated with microembolic HITS could be characterized, resulting in further criteria for the differentiation between microembolic signals and artifact in Doppler emboli detection. The sensitivity of the detection of these signals can be increased by high-resolution analysis of raw Doppler data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Land Cover Subpixel Change Detection using Hyperspectral Images Based on Spectral Unmixing and Post-processing

  The earth is continually being influenced by some actions such as flood, tornado and human artificial activities. This process causes the changes in land cover type. Thus, for optimal management of the use of resources, it is necessary to be aware of these changes. Today’s remote sensing plays key role in geology and environmental monitoring by its high resolution, wide covering and low cost...

متن کامل

Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.

BACKGROUND AND PURPOSE Doppler emboli detection is an established technique, but the nature of the underlying embolic material remains unclear. The intensity and spectral distribution of emboli signals could help to distinguish between signals arising from formed and gaseous emboli. We undertook this study to develop and evaluate a differentiation algorithm based on the spectral characteristics...

متن کامل

Object Level Strategy for Spectral Quality Assessment of High Resolution Pan-sharpen Images

Panchromatic and multi-spectral images produced by the remote sensing satellites are fused together to provide a multi-spectral image with a high spatial resolution at the same time. The spectral quality of the fused images is very important because the quality of a large number of remote sensing products depends on it. Due to the importance of the spectral quality of the fused images, its eval...

متن کامل

Computerized detection of cerebral emboli and discrimination from artifact using Doppler ultrasound.

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can detect circulating cerebral emboli. Monitoring of patients with potential embolic sources may allow identification of high-risk patients who can then be selected for prophylactic treatment. However, practical patient monitoring will require automated programs that can detect emboli and differentiate them from artifact. METHODS A new o...

متن کامل

VHR Semantic Labeling by Random Forest Classification and Fusion of Spectral and Spatial Features on Google Earth Engine

Semantic labeling is an active field in remote sensing applications. Although handling high detailed objects in Very High Resolution (VHR) optical image and VHR Digital Surface Model (DSM) is a challenging task, it can improve the accuracy of semantic labeling methods. In this paper, a semantic labeling method is proposed by fusion of optical and normalized DSM data. Spectral and spatial featur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 1998