Measurement of stroke volume from pulmonary artery pressure record in man.
نویسندگان
چکیده
Stroke volume was determined from the pulmonary artery pressure record by application of the pulse contour method. Pulmonary artery pressure records were obtained in 17 patients using a high fidelity catheter-tip pressure transducer and simultaneous measurements of cardiac output were obtained from indicator dilution curves. The formula used was SV = KP sa (i plus T s/Td) where Psa is the planimetered area beneath the systolic portion of the pulmonary artery pressure curve. Ts and Td are the durations of systole and diastole, and K is a constant. Stroke volume was altered by isometric handgrip exercise and/or pharmacological agents in 15 patients. Serial measurementswere made in 2 patients in acute pulmonary oedema after myocardial infarction. Comparison of a wide range of values of stroke volume by the pulse contour method with those obtained from dye dilution curves showed a good correlation (r plus 0.97, P smaller than 0.001) regression line y = 1.01 times - 0.47. Measurement of stroke volume from the pulmonary artery pressure contour is a technique of potential value in serial haemodynamic monitoring.
منابع مشابه
Measurement of instantaneous blood flow velocity and pressure in conscious man with a catheter-tip velocity probe.
SUMMARY Twenty-three patients were investigated during diagnostic right and left cardiac catheterization with an electromagnetic catheter-tip velocity probe. The catheter contained a pressure lumen for simultaneous measurements of intravascular pressure. Average peak and mean blood velocities were 66 and 11 cm/sec in the ascending aorta, 57 and 10 cm/sec in the pulmonary artery, 28 and 12 cm/se...
متن کاملRegulation of stroke volume during submaximal and maximal upright exercise in normal man.
To characterize the hemodynamic factors that regulate stroke volume during upright exercise in normal man, 24 asymptomatic male volunteers were evaluated by simultaneous right heart catheterization, radionuclide angiography, and expired gas analysis during staged upright bicycle exercise to exhaustion. From rest to peak exercise, oxygen consumption increased from 0.33 to 2.55 liters/min (7.7-fo...
متن کاملPrediction of volume response under open-chest conditions during coronary artery bypass surgery
INTRODUCTION Adequate fluid loading is the first step of hemodynamic optimization in cardiac patients undergoing surgery. Neither a clinical approach alone nor conventional parameters like central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) are thought to be sufficient for recognizing fluid deficiency or overload. The aim of this study was to evaluate the suitability of ...
متن کاملPulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.
OBJECTIVE Pulmonary artery occlusion pressure and central venous pressure have been considered to be reliable measures of left and right ventricular preload in patients requiring invasive hemodynamic monitoring. Studies in recent years have questioned the correlation between these estimates of ventricular filling pressures and ventricular end-diastolic volumes/cardiac performance variables in s...
متن کاملRight ventriculo-arterial coupling in repaired Fallot patients with pulmonary valve regurgitation before and after pulmonary valve implantation: a CMR study
Background Right ventricular-pulmonary arterial coupling plays an important role in the occurrence of right ventricular failure. Ventricular-arterial coupling is defined as Ea/ Emax. Ea is the effective arterial elastance and an index of the post-load, and includes vascular resistances, vessel compliance, vascular impedance, systolic and diastolic time intervals. Ea = (arterial end-systolic pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 37 1 شماره
صفحات -
تاریخ انتشار 1975