Investigating the effects of strap tension during non-invasive ventilation mask application: a combined biomechanical and biomarker approach

نویسندگان

  • Peter R Worsley
  • George Prudden
  • George Gower
  • Dan L Bader
چکیده

Non-invasive ventilation is commonly used for respiratory support. However, in some cases, mask application can cause pressure ulcers to specific features of the face, resulting in pain and reduced quality of life for the individual. This study investigated the effects of mask strap tension on the biomechanical and biomarker responses at the skin interface. Healthy participants (n = 13) were recruited and assigned two different masks in a random order, which were fitted with three strap conditions representing increments of 5 mm to increase tension. Masks were worn for 10 minutes at each tension followed by a 10-minute refractory period. Assessment at the device-skin interface included measurements of pressures at the nose and cheeks, temperature and humidity, a selection of inflammatory cytokine concentrations collected from sebum and scores of comfort. The results indicated significantly higher interface pressures at the bridge of the nose compared to the cheeks for both masks (p < 0.05), with nasal interface pressures significantly increasing with elevated strap tension (p < 0.05). One inflammatory cytokine, IL-1α, increased following mask application at the highest tension, with median increases from baselines ranging from 21 to 33%. The other cytokines revealed a less consistent trend with strap tension. The participants reported statistically greater discomfort during elevated strap tension. Temperature and humidity values under the mask were elevated from ambient conditions, although no differences were observed between mask type or strap tension. The bony prominence on the bridge of the nose represented a vulnerable area of skin during respiratory mask application. This study has shown that mask strap tension has a significant effect on the pressure exerted on the nose. This can result in discomfort and an inflammatory response at the skin surface. Further studies are required to investigate respiratory mask application for appropriate individuals with comorbidities.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the effects of cervical collar design and fit on the biomechanical and biomarker reaction at the skin

Background Research has shown that up to 33% of pressure ulcers (PUs) acquired in hospitals result from the application of a medical device. Cervical collars (C-collars) have been implicated in causing PUs, due to the mechanical force they apply to the skin. In order to improve our understanding of collar-related PUs, the present study aimed to assess the biomechanical, biochemical, and microcl...

متن کامل

The Effects of Music Therapy on Respiratory Comfort, Anxiety, and Depression During Non-Invasive Mechanical Ventilation Among Patients with Coronavirus Disease

Background: Hospitalized patients with Covid-19 may experience emotional problems and respiratory discomfort during mechanical ventilation. The aim of this study was to evaluate the effects of music therapy on respiratory comfort, anxiety, and depression among patients with Covid-19 under non-invasive mechanical ventilation. Methods: It was a randomized clinical trial. The subjects were 64 pat...

متن کامل

Efficiency and outcome of non-invasive versus invasive positive pressure ventilation therapy in respiratory failure due to chronic obstructive pulmonary disease

Background: Application noninvasive ventilation in the patients with exacerbation of chronic obstructive pulmonary disease (COPD) reduced mortality. This case-control study was designed to compare efficiency and outcome of non-invasive (NIV) versus invasive positive pressure ventilation (IPPV) in respiratory failure due to COPD Methods: The patients were assigned to NIV or IPPV intermittantl...

متن کامل

A novel non-invasive ventilation mask to prevent and manage respiratory failure during fiberoptic bronchoscopy, gastroscopy and transesophageal echocardiography

Fiberoptic bronchoscopy (for difficult intubation, bronchoalveolar lavage or biopsies), gastric endoscopies and transesophageal echocardiography (for transfemoral aortic valve replacement, MitraClip or left atrial appendage closure), are widespread diagnostic and therapeutic procedures. Non-invasive ventilation during upper endoscopies can be used to prevent or treat acute respiratory failure e...

متن کامل

Noninvasive reduction of open-book pelvic fractures by circumferential compression.

OBJECTIVES To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN Biomechanical investigation on human cadaveric specimens. SETTING Biomechanics laboratory. INTERVENTION Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016