Good short-term agreement between measured and calculated tracheal pressure.
نویسندگان
چکیده
BACKGROUND Tracheal pressure (P(tr)) is required to measure the resistance of the tracheal tube and the breathing circuit. P(tr) can either be measured with a catheter or, alternatively, calculated from the pressure-flow data available from the ventilator. METHODS Calculated P(tr) was compared with measured P(tr) during controlled ventilation and assisted spontaneous breathing in 18 healthy and surfactant-depleted piglets. Their lungs were ventilated using different flow patterns, tidal volumes (V(T)) and levels of positive end-expiratory pressure. RESULTS In terms of the root mean square error (RMS), indicating the average deviation of calculated from measured P(tr), the difference between calculated and measured P(tr) was 0.6 cm H(2)O (95%CI 0.58-0.65) for volume-controlled ventilation; 0.73 cm H(2)O (0.72-0.75) for pressure support ventilation; and 0.78 cm H(2)O (0.75-0.80) for bi-level positive airway pressure ventilation. CONCLUSION The good agreement between calculated and measured P(tr) during varying conditions, suggests that calculating P(tr) could help setting the ventilator and choosing the appropriate level of support.
منابع مشابه
CALCULATION OF OSMOTIC PRESSURE USING A CLOSED SYSTEM MODEL
In this work we have used a closed system model to derive an analytical equation for the osmotic pressure of two component electrolyte and non-electrolyte solutions. In order to do so, we have used an equation of state, known as the dense system equation of state (DSEOS), for the model system. Based on the model, a new definition is given for the osmotic pressure of a closed system. Good ag...
متن کاملHandcrafted cuff manometers do not accurately measure endotracheal tube cuff pressure
OBJECTIVE To test the agreement between two handcrafted devices and a cuff-specific manometer. METHODS The agreement between two handcrafted devices adapted to measure tracheal tube cuff pressure and a cuff-specific manometer was tested on 79 subjects. The cuff pressure was measured with a commercial manometer and with two handcrafted devices (HD) assembled with aneroid sphygmomanometers (HD1...
متن کاملمقایسه اثرات پروپوفول با سوفلوران در لولهگذاری بدون شل کننده عضلانی در کودکان
Background and aims: To compare intubating conditions and cardiovascular changes followinduction of anesthesia and tracheal intubation in patients receiving either lidocaine-remifentanilpropofolor lidocaine-remifentanil-sevoflurane prior to induction.Methods and materials: In a randomized, double-blind study 75 healthy children patientswere assigned to one of two groups: lidocaine 1.5 mg·kg-1, ...
متن کاملA study on behavior of block pavement using 3D finite element method
Three dimensioned finite element analysis were conducted on concrete block paving. In order to verify the calculated results, an experimental case study was analyzed. Good agreement was observed between the measured and the calculated results. Based on the finite element analysis results and available failure models, comprehensive design charts were developed for port and industrial pavement wh...
متن کاملImmediate, short‐, and long‐term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome
BACKGROUND Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. OBJECTIVES Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of anaesthesia
دوره 91 2 شماره
صفحات -
تاریخ انتشار 2003