Distribution of IOP measured with an air puff tonometer in a young population

نویسندگان

  • Hassan Hashemi
  • Mehdi Khabazkhoob
  • Payam Nabovati
  • Negareh Yazdani
  • Hadi Ostadimoghaddam
  • Ehsan Shiralivand
  • Akbar Derakhshan
  • AbbasAli Yekta
چکیده

Purpose To determine the normal range of intraocular pressure (IOP) in the young and its association with certain corneal parameters using a non-contact device. Methods Subjects were selected from students of Mashhad University of Medical Sciences through stratified sampling. All participants had visual acuity testing, corneal imaging, a comprehensive slit-lamp examination by an ophthalmologist, and IOP measurement using a non-contact air-puff tonometer. Results Of the 1280 invitees, 1073 (83.8%) participated, and 1027 were eligible. Mean IOP was 16.38 mmHg [95% confidence interval (CI): 16.22-16.53] in the total sample, 16.14 mmHg (95% CI: 15.84-16.45) in men, and 16.48 mmHg (95% CI: 16.31-16.66) in women. There was a significant IOP difference between myopes and emmetropes (P = 0.031). Based on the multiple linear regression model, IOP associated directly with age and central corneal thickness (CCT), and inversely with corneal diameter, spherical equivalent (SE), and keratoconus. Based on standardized coefficients of the regression model, CCT and SE had the strongest association with IOP. Conclusions In the present study, we demonstrated the IOP distribution in a young population using a non-contact method. CCT and SE were strongly associated with IOP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure measurement: Goldmann Applanation Tonometer vs non contact airpuff tonometer.

BACKGROUND An accurate assessment of Intraocular pressure (IOP) is vital in establishing diagnosis of Glaucoma and decision making regarding various treatment modalities available. The purpose of this study is to compare Goldmann Applanation Tonometer (GAT) with Air puff tonometer. METHODS Cross-sectional comparative study conducted. 73 eyes from 73 patients were included in this study and in...

متن کامل

Comparative evaluation of intraocular pressure with an air-puff tonometer versus a Goldmann applanation tonometer

PURPOSE Tonometry, or measurement of intraocular pressure (IOP), is one of the most important examination procedures in ophthalmic clinics, and IOP is an important parameter in the diagnosis of glaucoma. Because there are numerous types of tonometer available, it is important to evaluate the differences in readings between different tonometers. Goldmann applanation tonometers (GATs) and noncont...

متن کامل

Air Pressure–Induced Iridocornea Contact in a Patient With Primary Angle Closure Observed With a Dynamic Scheimpflug Analyzer

PURPOSE To report air pressure-induced corneal deformation and iridocornea contact in eyes with primary angle closure (PAC) during intraocular pressure (IOP) measurement performed using a novel noncontact tonometer. METHODS A single case report. RESULTS We report a patient with bilateral angle closure. One eye had acute PAC and the other had PAC. The latter was evaluated by the movements of...

متن کامل

Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneas

A new technique is presented for the non-invasive imaging of the dynamic response of the cornea to an air puff inducing a deformation. A spectral OCT instrument combined with an air tonometer in a non-collinear configuration was used to image the corneal deformation over full corneal cross-sections, as well as to obtain high speed measurements of the temporal evolution of the corneal apex. The ...

متن کامل

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2018