Detection of early lung impairment with aerosol bolus dispersion.
نویسندگان
چکیده
The broadening of inhaled aerosol boluses (aerosol bolus dispersion) during respiration provides a noninvasive measure of convective gas mixing in the lungs. In this study, the sensitivity and specificity of this technique for the diagnosis of early lung impairment due to cigarette smoking was evaluated. Two hundred and sixteen randomly selected subjects (126 smokers and 90 nonsmokers) were investigated with aerosol dispersion in comparison to conventional lung function tests. The cumulative cigarette consumption of the subjects was quantified by "pack-years" (PY). Smokers were classified into the following groups: 0 < PY < or = 10; 10 < PY < or = 20; 20 < PY < or = 30; and PY > 30. Forced expiratory volume in one second (FEV1), maximal expiratory flow at 25, 50 and 75% vital capacity (MEF25, MEF50 and MEF75) decreased significantly with increasing cigarette consumption. In comparison to nonsmokers, FEV1 was significantly reduced in smokers of 10 < PY < or = 30, and MEF75 was significantly reduced in smokers of PY > 20. Aerosol bolus dispersion increased with increasing PY. For all groups of smokers, even those with PY < 10, bolus dispersion was significantly increased in comparison to lifelong nonsmokers, indicating alterations in convective gas mixing in the lungs. Calculation of receiver operating characteristics for the lung function parameters under consideration showed that bolus dispersion has a higher sensitivity and specificity than conventional lung function parameters. Hence, the aerosol bolus dispersion test could be a promising epidemiological tool to study early abnormalities in intrapulmonary gas mixing due to environmental factors.
منابع مشابه
Aerosol bolus dispersion in healthy subjects.
Aerosol bolus dispersion is a physiological test of lungs, which uses monodisperse submicron particles to measure intrapulmonary convective gas mixing. In this study, aerosol bolus dispersion was measured in healthy subjects in order to assess reference values for possible clinical applications, to assess the reproducibility of these values, and to identify physical and physiological factors in...
متن کاملEffect of ventilation distribution on aerosol bolus dispersion and recovery.
It has been speculated that convective ventilatory inhomogeneities are an important factor influencing aerosol bolus behavior in the compromised lung. Multiple-breath 133Xe washout (MBWXe) is a commonly accepted test of ventilation distribution. By comparing aerosol bolus parameters to MBWXe in 9 healthy subjects and 14 cystic fibrosis patients with mild-to-moderate airway obstruction, we have ...
متن کاملAerosol bolus dispersion and effective airway diameters in mildly asthmatic children.
The contribution of aerosol techniques, the estimation of aerosol bolus dispersion and effective airway dimensions, to the clinical diagnosis of paediatric asthma was studied. In 47 children, aged 11 +/- 2 yrs, with mild asthma (forced expiratory volume in one second (FEV1) 83 +/- 9% of forced vital capacity (FVC)) effective airway diameters were derived from the recovery of inhaled 1 micron se...
متن کاملAerosol Bolus Dispersion and Recovery in a Human and Dog Airway Cast
In recent years methods in lung diagnostics have been developed using the aerosol bolus inhalation technique (Heyder et al., 1988; Anderson et al., 1989; Schulz et al., 1995; Blanchard 1996). A bolus is a small volume of aerosol sandwiched in particle-free air and inhaled into different volumetric regions of the lung. During inhalation and exhalation the original small bolus is dispersed over a...
متن کاملDeposition and dispersion of 1-μm aerosol boluses in the human lung: effect of micro- and hypergravity
Darquenne, Chantal, John B. West, and G. Kim Prisk. Deposition and dispersion of 1-μm aerosol boluses in the human lung: effect of microand hypergravity. J. Appl. Physiol. 85(4): 1252–1259, 1998.—We performed bolus inhalations of 1-μm particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (μG) and in ,1.6 G. Boluses of ,70 ml were inhaled at different p...