X-ray detector based on a bulk micromachined photodiode combined with a scintillating crystal

نویسندگان

  • J G Rocha
  • C G J Schabmueller
  • N F Ramos
  • J H Correia
چکیده

In this paper we report on the design, fabrication, assembly and testing of an x-ray detector based on a bulk micromachined photodiode (BMMPD) with a cavity filled with a scintillating crystal. The x-ray photons that reach the detector are first converted to visible light by the scintillating crystal. The visible light is then detected by the BMMPD, producing an electric current with a value proportional to the incident x-ray intensity. Tests were performed using two x-ray setups: an experimental setup and a professional setup. The first was powered with a maximum voltage of 35 kV, and a current ranging to 1 mA, and the second was powered with voltages from 40 to 60 kV and currents ranging from 10 to 55 mA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CMOS X-rays detector array based on scintillating light guides

This paper describes a pixel imaging array consisting in 400 m × 400 m photodiodes fabricated in CMOS technology. An array of scintillating CsI:Tl crystals is placed above the photodiodes. These crystals are encapsulated in aluminum walls, forming a light path that guides the visible light produced by the scintillating crystal into the photodiodes. In this way, the X-ray energy is first convert...

متن کامل

A Geiger-mode avalanche photodiode array for X-ray photon correlation spectroscopy.

X-ray photon correlation spectroscopy (XPCS) provides an opportunity to study the dynamics of systems by measuring the temporal fluctuations in a far-field diffraction pattern. A two-dimensional detector system has been developed to investigate fluctuations in the frequency range of several Hz to kHz. The X-ray detector system consists of a thin 100 microm scintillation crystal coupled to a Gei...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

x / 02 06 01 8 v 1 1 0 Ju n 20 02 Multi - energy radiography on the basis of “ scintillator - photodiode ” detectors

For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintil-lators ZnSe(T e) and CsI(...

متن کامل

N ov 2 00 2 Multi - energy radiography on the basis of “ scintillator - photodiode ” detectors

For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintil-lators ZnSe(T e) and CsI(...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003