The Parallax Effect in the Evaluation of Range of Motion in Lumbar Total Disc Replacement
نویسندگان
چکیده
BACKGROUND Range of motion (ROM) has been shown to influence clinical outcomes of total disc replacement (TDR). While the parallax effect in image acquisition has been shown in the literature to influence the accuracy of a variety of measurements, this concept has not been investigated in the assessment of ROM analysis following TDR. We performed an evaluation of the influence of radiograph beam angle on "by hand" and on "gold standard" flexionextension ROM measurements in lumbar total disc replacement. The purpose of this study is to determine (1) the influence of X-ray beam angle on index level angle (ILA) measurements in lumbar TDR using the keel method, and (2) whether the out-of-plane radiographic beam effects cause a difference between true and calculated range of motion. METHODS Eight blinded orthopaedic surgeons used the keel method to calculate ROM measurements from radiographs of a flexible Sawbones model (Pacific Research Laboratories, Inc., Vashon, Washington) implanted with a ProDisc-L device (Synthes Spine, West Chester, Pennsylvania). Radiographs were obtained at beam angles of 0°, 5°, 10°, and 15° in the sagittal plane from the device center. Calculations were compared to measurements obtained by a validated digitized software method (Quantitative Motion Analysis, QMA, Medical Metrics, Inc., Houston, Texas). Inter- and intraobserver precision and accuracy were determined. RESULTS Compared with QMA, the radiographic keel method had an average error of 3.7°. No significant effect of variation in beam angle on interobserver precision (N = 16, P = .92) or accuracy (N = 16, P = 0.86) or intraobserver precision (N = 8, P = .09) or accuracy (N = 8, P = 0.07) of ROM measurements was identified. Repeat testing with QMA also revealed no effect of parallax and resulted in nearly identical ROM measurements. CONCLUSIONS Accuracy and precision of the keel method to determine ROM from index level angle measurements after TDR was not affected by increases in X-ray beam angles up to 15° from the device center. CLINICAL RELEVANCE Our study demonstrates that range of motion measurements are not influenced by parallax effect when using the keel method to determine index level angle measurements in lumbar total disc replacement.
منابع مشابه
Prevalence and Severity of Preoperative Disabilities in Iranian Patients with Lumbar Disc Herniation
Background: Literature recommends that refractory cases with lumbar disc herniation and appropriate indications are better to be treated surgically, but do all the patients throughout the world consent to the surgery with a same disability and pain threshold? We aim to elucidate the prevalence and severity of disabilities and pain in Iranian patients with lumbar disc herniation who have conse...
متن کاملEvaluation of The Validity and Reliability of The Questionnaire to Assess The Knowledge, Attitude and Practice of Patients' Postoperative Care of Lumbar Disc or Discectomy
Introduction: Lumbar disc herniation surgery is one of the most common spinal surgeries and postoperative care behaviors play an important role in the healing process. This study aimed to design and psychometric a questionnaire to assess patients' postoperative care of lumbar disc or discectomy. Methods: This is a psychometric study and was conducted in two parts of questionnaire design and it...
متن کاملA comparative study of trunk proprioception between patients with chronic non-specific low back pain and discopathic low back pain
Introduction: Low back pain is one of the most common disorders in modern society. Disturbed properioception can be a possible cause of low back pain and can cause recurrence of low back pain. Previous studies have shown that low back pain reduces proprioception due to instability in the low back. Since the degenerative process of disc herniation is one of the important factors in exacerbating ...
متن کاملThe activL® Artificial Disc: a next-generation motion-preserving implant for chronic lumbar discogenic pain
Degeneration of the lumbar intervertebral discs is a leading cause of chronic low back pain in adults. Treatment options for patients with chronic lumbar discogenic pain unresponsive to conservative management include total disc replacement (TDR) or lumbar fusion. Until recently, only two lumbar TDRs had been approved by the US Food and Drug Administration - the Charité Artificial Disc in 2004 ...
متن کاملComparison the Recurrence Rate of Intervertebral Disc Herniation in Two Surgical Methods of Hemi laminectomy and Partial Laminectomy
Background & Aims: Between 5% and 15% of patients with low back pain suffer from lumbar disc herniation, so intervertebral disc disease is one of the most common causes of low back pain. Surgical intervention for lumbar disc herniation is recommended in patients with severe symptoms and has hopeful results. Although surgery can reduce pain and improve physical function in the short term, its lo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2008