Integrating coronary anastomotic connectors and robotics toward a totally endoscopic beating heart approach: review of 120 cases.
نویسندگان
چکیده
BACKGROUND Endoscopic coronary bypass has been a difficult procedure to perform. The recent introduction of the Intuitive EndoWrist stabilizer (Intuitive Surgical, Sunnyvale, CA) has facilitated this procedure robotically on the beating heart. The addition of anastomotic connectors allows a significant improvement in the execution of this technically demanding procedure. We report on our first 120 cases of totally endoscopic, beating heart connector coronary artery bypass grafting integrating these technologies. METHODS From January 2008 to April 2010, 120 patients (age range 43 to 86 years, 72% male) underwent either single or multivessel all arterial, totally endoscopic coronary artery bypass grafting using the da Vinci robot with the aid of the Flex A distal anastomotic device (Cardica, Redwood City, CA). Patients with multivessel disease involving branches of the right coronary and circumflex arteries underwent hybrid revascularization with stents. Early and midterm clinical outcomes were evaluated for all patients. Eighty-five internal mammary artery grafts in 68 patients were evaluated at a mean of 4 months using multidetector computed tomography and formal angiography (in 18 hybrid patients). RESULTS Mean hospital stay was 3.3±2.4 days. There was 1 postoperative death (the same patient had a stroke secondary to carotid disease), and 1 postoperative myocardial infarction. Two patients were converted to minithoracotomy and 1 patient was converted to sternotomy. One patient required cardiopulmonary bypass support through the femoral cannulation during the procedure. Mean intraoperative transit time flow in all the internal mammary artery grafts was 76 cc/minute±43, and pulsatility index of 1.5±0.5. Of the 85 grafts evaluated angiographically, 80 were patent at a mean of 4 months (94.1%). CONCLUSIONS Totally endoscopic beating heart connector coronary bypass using the da Vinci robot with the Flex A anastomotic device is a safe and reproducible procedure. A significant learning curve is involved and experience with anastomotic devices in the open setting is necessary. Long-term follow-up of graft patency and patient outcomes is warranted.
منابع مشابه
Facilitated endoscopic beating heart coronary artery bypass grafting using a magnetic coupling device.
BACKGROUND Suturing of a coronary anastomosis in totally endoscopic coronary artery bypass grafting on the beating heart is technically demanding. The potential benefits of the endoscopic Magnetic Vascular Positioner device (Ventrica, Inc, Fremont, Calif) to facilitate construction of a coronary anastomosis in a closed chest environment were evaluated. METHODS Totally endoscopic coronary arte...
متن کاملRobotically enhanced coronary artery bypass surgery
Robotically enhanced telemanipulation surgery is a rapidly developing technique which enables totally endoscopic cardiac surgery with utmost precision and perfection on both beating heart and arrested heart. Between December 2002 and September 2006, 268 patients underwent robotically enhanced coronary artery bypass surgery using the da Vinci telemanipulation system. Fourteen patients underwent ...
متن کاملEarly and midterm results of totally endoscopic coronary artery bypass grafting on the beating heart.
OBJECTIVE Despite the early introduction of totally endoscopic coronary artery bypass on the beating heart, only a limited number of cases have been performed. The limiting factor has been the concern about safety and graft patency of the anastomosis. This study describes our experience with totally endoscopic coronary artery bypass on the beating heart with robotic assistance and its early and...
متن کاملOne hundred sixty-four consecutive beating heart totally endoscopic coronary artery bypass cases without intraoperative conversion.
BACKGROUND Totally endoscopic coronary artery bypass graft (TECABG) surgery has been found to be feasible, but numerous reports associate the procedure with high conversion rates. This report aims to discuss 164 consecutive beating heart TECABG cases without intraoperative conversion to open CABG as well as potential steps to minimize conversion. METHODS Since July 2008, 164 consecutive beati...
متن کاملRobotically-Assisted Coronary Artery Bypass Grafting
Objectives. Robotic surgery enables to perform coronary surgery totally endoscopically. This report describes our experience using the da Vinci system for coronary artery bypass surgery. Methods. Patients requiring single-or-double vessel revascularization were eligible. The procedure was performed without cardiopulmonary bypass on a beating heart. Results. From April 2004 to May 2008, fifty-si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Annals of thoracic surgery
دوره 92 3 شماره
صفحات -
تاریخ انتشار 2011