Determination of an Amazon Hot Reference Target for the On-Orbit Calibration of Microwave Radiometers

نویسندگان

  • SHANNON T. BROWN
  • CHRISTOPHER S. RUF
چکیده

A physically based model is developed to determine hot calibration reference brightness temperatures (TBs) over depolarized regions in the Amazon rain forest. The model can be used to evaluate the end-to-end calibration of any satellite microwave radiometer operating at a frequency between 18 and 40 GHz and angle of incidence between nadir and 55°. The model is constrained by Special Sensor Microwave Imager (SSM/I) TBs measured at 19.35, 22.2, and 37.0 GHz at a 53° angle of incidence and extrapolates/interpolates those measurements to other frequencies and incidence angles. The rms uncertainty in the physically based model is estimated to be 0.57 K. For instances in which coincident SSM/I measurements are not available, an empirical formula has been fit to the physical model to provide hot reference brightness temperature as a function of frequency, incidence angle, time of day, and day of year. The empirical formula has a 0.1-K rms deviation from the physically based model for annual averaged measurements and at most a 0.6-K deviation from the model for any specific time of day or day of year.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the best-fitting reference orbit for a LEO satellite using the Lagrange coefficients

Linearization of the nonlinear equations and iterative solution is the most well-known scheme in many engineering problems. For geodetic applications of the LEO satellites, e.g. the Earth’s gravity field recovery, one needs to provide an initial guess of the satellite location or the so-called reference orbit. Numerical integration can be utilized for generating the reference orbit if a satelli...

متن کامل

Comparison of microwave radiometer brightness temperature over a hot reference area

Nadir-looking microwave radiometers are flown on different altimeter missions to correct the altimeter range for water vapor and cloud liquid water path delay in the troposphere. Actually four sensors, TOPEX, JASON-1, ERS2, and ENVISAT micro-wave radiometers (MWR) provide continuous measurements and the aim of this paper is to compare their measured brightness temperatures over the same hot ref...

متن کامل

Detection of calibration drifts in spaceborne microwave radiometers using a vicarious cold reference

The coldest possible brightness temperatures observed by a downward-looking microwave radiometer from space are often produced by calm oceans under cloud-free skies and very low humidity. This set of conditions tends to occur with sufficient regularity that an orbiting radiometer will accumulate a useful number of observations within a period of a few days to weeks. Histograms of the radiometer...

متن کامل

Calibration of Microwave Radiometers: an Overview

INTRODUCTION This paper describes 1) the progress of the work of the IEEE Geoscience and Remote Sensing Society (GRSS) Instrumentation and Future Technologies Technical Committee (IFT-TC) Microwave Radiometer Working Group and 2) an overview of the calibration issues of microwave radiometers as an introduction to a dedicated session.

متن کامل

Optimal Calibration of Radiometers Using System Identification Techniques

Microwave radiometers are valuable for obtaining geophysical information such as the ocean surface salinity, stratiform precipitation, water vapor, temperature, soil moisture, vegetation cover, and others [1]. These environmental monitoring applications of passive microwave remote sensing systems require precision measurements of brightness temperatures over a range of more than 300K with absol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005