Radiation Exposure During Uterine Fibroid Embolization (UFE): A Confounder-Controlled Comparison Between a State-of-the-Art Angiography Unit and a Conventional Angiography unit Strahlenexposition während Uterusmyomembolisation (UME): Ein Störgrößen-kontrollierter Vergleich zwischen einem hochmodernen Angiografiesystem und einem konventionellen Angiografiesystem
نویسندگان
چکیده
Purpose To compare radiation exposure of a state-of-the-art and a conventional angiography unit in patients undergoing uterine fibroid embolization (UFE). Materials and Methods Between January 2009 and December 2016, 286 patients underwent UFE in our Interdisciplinary Fibroid Center. The inclusion criteria for this retrospective analysis were first-time transarterial embolization for symptomatic fibroids, bilateral embolization, procedures applying a state-of-the-art (Group 1) or a conventional angiography unit (Group 2), and bilateral technical success with an adequate embolization endpoint after the injection of microspheres. Study endpoints included radiation exposure, major complications, morphological success (MRI), and clinical success (questionnaire on quality-of-life). Propensity score matching controlled for confounders. Results The inclusion criteria were met by 58 (Group 1) and 177 (Group 2) patients. After propensity score matching, there was no significant difference between Group 1 (n = 46) and Group 2 (n = 92) regarding age, body-mass index, volume of the dominant fibroid and the uterus, fluoroscopy time, and amount of embolic agent (p ≥ 0.10 each). The dose-area product was significantly lower in Group 1 than in Group 2 (1159.0 cGycm2 vs. 3123.5 cGycm2; p < 0.001), while major complication rates (both groups 0%) and dominant fibroid devascularization (both groups 100%) were equal (p > 0.99). There were no significant differences between both groups regarding shrinkage of the dominant fibroid and the uterus and no relevant differences regarding patient-reported quality-of-life. Conclusion A state-of-the-art angiography unit has the potential to reduce radiation exposure in patients undergoing UFE without increasing the risk of major complications and with comparably high morphological and clinical success. Key Points ▪ A state-of-the-art angiography unit potentially reduces radiation exposure in patients undergoing UFE. ▪ Reduced radiation exposure does not seem to negatively influence the rate of major complications. ▪ Reduced exposure does not seem to negatively affect morphological and clinical success. Citation Format ▪ Sommer C, Voigt W, Oliger MK et al. Radiation Exposure During Uterine Fibroid Embolization (UFE): A ConfounderControlled Comparison Between a State-of-the-Art Angiography Unit and a Conventional Angiography unit. Fortschr Röntgenstr 2017; DOI 10.1055/s-0043-119036
منابع مشابه
Reduction of Radiation Exposure for the Examiner in Angiography using a Direct Dosimeter Reduktion der Strahlenexposition für den Untersucher in der Angiografie durch Anwendung eines direkten Dosimeters
Ziel: Prospektive Evaluation der Strahlenexposition des Untersuchers in der Angiografie. Kann durch Anwendung eines direkten Dosimeters mit akustischem Warnsignal eine Reduktion der Strahlenexposition erreicht werden? Material und Methoden: Zur Auswertung kommen insgesamt 183 diagnostische und interventionelle Angiografien der unteren Extremitäten unter Anwendung eines direkten Dosimeters. Die ...
متن کاملPatient radiation exposure during uterine fibroid embolization and the dose attributable to aortography.
The techniques used for uterine fibroid embolization (UFE) have rapidly evolved during the past decade. One source of uncertainty in the UFE technique has been the importance of the contribution of the ovarian artery to the blood supply of the uterus and fibroids. Although conventional aortography is often used after embolization to assess for collateral arterial supply, few patients are identi...
متن کاملQuantitativer und qualitativer Vergleich von Anforderungen bei agilen und konventionellen Softwareprojekten
Einleitung In der Softwareentwicklung hängt der Erfolg oder Misserfolg eines Projektes wesentlich davon ab, ob die Wünsche des Kunden umgesetzt wurden oder nicht. Im Kundengespräch werden die Anforderungen an das System erhoben, die letztendlich die Wünsche des Kunden widerspiegeln. Um den Kunden zufriedenzustellen, müssen diese Anforderungen mit hoher Priorität umgesetzt werden. In konventione...
متن کاملPreprocedural MRI and MRA in planning fibroid embolization.
This pictorial review aims to discuss and illustrate the up-to-date use of preprocedural magnetic resonance imaging (MRI) in selecting patients and planning uterine artery embolization (UAE). The merits of magnetic resonance angiography (MRA) in demonstrating the pelvic vasculature to guide UAE are highlighted. MRI features of fibroids and their main differential diagnoses are presented. Fibroi...
متن کاملLaserpointer-Interaktion für große, hochauflösende Displays
Aufgrund des limitierten Sehvermögens des Menschen muss sich ein Anwender vor großen, hochauflösenden Displays frei bewegen können, um kleinste Details pixelgenau wahr zu nehmen oder einen Überblick über die gesamte Darstellungsfläche von mehreren Quadratmetern zu erhalten. Im Gegensatz zu konventionellen Eingabegeräten wie Maus und Tastatur beschränken Laserpointer den Anwender nicht in seiner...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017