Frictional resistance between orthodontic brackets and archwire: an in vitro study.

نویسندگان

  • Nadeem Husain
  • Avinash Kumar
چکیده

AIM The purpose of this investigation was to determine the kinetic frictional resistance offered by stainless steel and Titanium bracket used in combination with rectangular stainless steel wire during in vitro translatory displacement of brackets. MATERIALS AND METHODS In this study. Brackets: (All brackets used had a torque of - 7° and an angulation of 0°): (1) Dynalock (Unitek) 0.018'' slot, 3.3 mm bracket width, (2) Mini Uni-Twin (Unitek) 0.018'' slot, 1.6 mm bracket width, (3) Ultra-Minitrim (Dentaurum) 0.022'' slot 3.3 mm bracket width, (4) Titanium (Dentaurum) 0.022'' slot, 3.3 mm bracket width. WIRES: (1) 0.016 x 0.022'' stainless steel (Dentaurum), (2) 0.017 x 0.025''stainless steel (Unitek), (3) 0.018 x 0.025'' stainless steel (Dentaurum), elastomeric modules (Ortho Organisers), 0. 009'' stainless steel ligature wires, hooks made of 0.021 x 0.025'' stainless steel wires, super glue to bond the hooks to the base of the bracket, acetone to condition the bracket and wires before testing and artificial saliva. Brackets were moved along the wire by means of an Instron universal testing machine (1101) and forces were measured by a load cell. All values were recorded in Newtons and then converted into gms (1N-102 gm). 200 gm was then subtracted from these values to find out the frictional force for each archwire/bracket combination. For each archwire/ bracket combination three readings were taken under wet and dry condition and also with stainless steel ligature and elastomeric modules separately. RESULTS The results showed that narrow brackets generated more friction than wider brackets. Frictional force was directly proportional to wire dimension. Titanium brackets generated more friction than stainless steel brackets. Archwire and bracket ligated with elastomeric module generated more friction than when ligated with stainless steel ligature wire. Frictional forces in the wet condition were greater than in the dry condition for all archwire to bracket combinations. CONCLUSION Frictional force was seen to be inversely proportional to bracket width, frictional force was inversely proportional to bracket width, and in the wet condition were greater than in the dry condition for all archwire to bracket combinations. CLINICAL SIGNIFICANCE This study of friction is its role in lessening the force actually received by a tooth from an active component such as a spring, loop or elastic. Hence greater applied force is needed to move a tooth with a bracket archwire combination demonstrating high magnitudes of friction compared with one with a low frictional value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Comparative Evaluation of Frictional forces between different Archwire-bracket Combinations

Introduction: During sliding mechanics, frictional resistance is an important counterforce to orthodontic tooth movement; which must be controlled to allow application of light continuous forces. objective: To investigate static and kinetic frictional resistance between three orthodontic brackets: ceramic, self-ligating, and stainless steel, and three 0.019×0.025” archwires: stainless steel, ni...

متن کامل

Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...

متن کامل

Friction between various self-ligating brackets and archwire couples during sliding mechanics.

INTRODUCTION The aim of this study was to evaluate the frictional resistance between active and passive self-ligating brackets and 0.019 × 0.025-in stainless steel archwire during sliding mechanics by using an orthodontic sliding simulation device. METHODS Maxillary right first premolar active self-ligating brackets In-Ovation R, In-Ovation C (both, GAC International, Bohemia, NY), and SPEED ...

متن کامل

Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

OBJECTIVE To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. METHODS Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2011