Test of a stand-off laser-induced breakdown spectroscopy sensor for the detection of explosive residues on solid surfaces
نویسندگان
چکیده
The detection and characterization of energetic materials at distances up to 45 m using stand-off laser induced breakdown spectroscopy (LIBS) has been demonstrated. A field-portable open-path LIB spectrometer working under a coaxial configuration was used. A preliminary study allowed choosing a single-pulse laser source over a double-pulse system as the most suitable source for the stand-off analysis of organic samples. The C2 Swan system, as well as the hydrogen, oxygen and nitrogen emission intensity ratios were the necessary parameters to identify the analyte as an organic explosive, organic non-explosive and non-organic samples. O/N intensity ratios of 2.9 and 2.16 with relative standard deviations of 4.03% and 8.36% were obtained for 2,4-dinitrotoluene and aluminium samples, respectively. A field test with known samples and a blind test were carried out at a distance of 30 m from the sample. Identification of energetic compounds in such conditions resulted in 19 correct results out of 21 samples.
منابع مشابه
Laser-induced breakdown spectroscopy for detection of explosives residues: a review of recent advances, challenges, and future prospects.
In this review we discuss the application of laser-induced breakdown spectroscopy (LIBS) to the problem of detection of residues of explosives. Research in this area presented in open literature is reviewed. Both laboratory and field-tested standoff LIBS instruments have been used to detect explosive materials. Recent advances in instrumentation and data analysis techniques are discussed, inclu...
متن کاملClassification of explosive residues on organic substrates using laser induced breakdown spectroscopy.
Standoff laser induced breakdown spectroscopy (LIBS) has previously been used to classify trace residues as either hazardous (explosives, biological, etc.) or benign. Correct classification can become more difficult depending on the surface/substrate underneath the residue due to variations in the laser-material interaction. In addition, classification can become problematic if the substrate ma...
متن کاملUse of laser-triggered gold nanoparticle-grafted dual light and temperature-responsive polymeric sensor for the recognition of thioguanine as anti-tumor agent
Objective(s): Today, there is an urgent need for improved sensor materials for drug sensing and effective monitoring and interventions in this area are highly required to struggle drug abuse. The present study aimed to synthesize a thioguanine-responsive sensor based on a nanocomposite consisting of AuNP-grafted light- and temperature-responsive poly butylmethacrylate-co-acrylamide-co-methacryl...
متن کاملThe effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy
The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005