BACKGROUND Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice. METHODS We randomly assigned 1845 patients undergoing PCI to receive either a bioresorbable vascular scaffold (924 patients) or a metallic stent (921 patients). The primary end point was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). The data and safety monitoring board recommended early reporting of the study results because of safety concerns. This report provides descriptive information on end-point events. RESULTS The median follow-up was 707 days. Target-vessel failure occurred in 105 patients in the scaffold group and in 94 patients in the stent group (2-year cumulative event rates, 11.7% and 10.7%, respectively; hazard ratio, 1.12; 95% confidence interval [CI], 0.85 to 1.48; P=0.43); event rates were based on Kaplan-Meier estimates in time-to-event analyses. Cardiac death occurred in 18 patients in the scaffold group and in 23 patients in the stent group (2-year cumulative event rates, 2.0% and 2.7%, respectively), target-vessel myocardial infarction occurred in 48 patients in the scaffold group and in 30 patients in the stent group (2-year cumulative event rates, 5.5% and 3.2%), and target-vessel revascularization occurred in 76 patients in the scaffold group and in 65 patients in the stent group (2-year cumulative event rates, 8.7% and 7.5%). Definite or probable device thrombosis occurred in 31 patients in the scaffold group as compared with 8 patients in the stent group (2-year cumulative event rates, 3.5% vs. 0.9%; hazard ratio, 3.87; 95% CI, 1.78 to 8.42; P<0.001). CONCLUSIONS In this preliminary report of a trial involving patients undergoing PCI, there was no significant difference in the rate of target-vessel failure between the patients who received a bioresorbable scaffold and the patients who received a metallic stent. The bioresorbable scaffold was associated with a higher incidence of device thrombosis than the metallic stent through 2 years of follow-up. (Funded by Abbott Vascular; AIDA ClinicalTrials.gov number, NCT01858077 .).
منابع مشابه
Appropriate use of bioresorbable vascular scaffolds in percutaneous coronary interventions: a recommendation from experienced users
Percutaneous coronary interventions (PCI) have become a reliable revascularisation option to treat ischaemic coronary artery disease. Drug-eluting stents (DES) are widely used as first choice devices in many procedures due to their established good medium to long term outcomes. These permanent implants, however, do not have any residual function after vascular healing following the PCI. Beyond ...
متن کاملBioresorbable vascular scaffold versus metallic stent in percutaneous coronary intervention: results of the AIDA trial
Drug-eluting stents have significantly improved the long-term outcomes of percutaneous coronary intervention (PCI) by decreasing the excessive growth of neointima. However, conventional stents have some limitations. PCI with a bioresorbable vascular scaffold (BVS) has emerged as an alternative since the presence of the prosthesis in the coronary artery is transient. A US Food and Drug Administr...
متن کاملBioresorbable vascular scaffold implantation in acute coronary syndromes: clinical evidence, tips and tricks
Percutaneous coronary intervention (PCI) with a drug-eluting stent (DES) is routine treatment for patients with acute coronary syndromes (ACS). However, permanent metallic caging of the vessel has several shortcomings, such as side branch jailing and impossibility of late lumen enlargement. Moreover, DES PCI is affected by vasomotion impairment. In ACS a high thrombus burden and vasospasm lead ...
متن کاملBioresorbable Vascular Scaffolds for Coronary Revascularization.
Contemporary metallic drug-eluting stents are associated with very good 1-year outcomes but an ongoing risk of stent-related adverse events (thrombosis, myocardial infarction, restenosis) after 1 year. The pathogenesis of these very late events is likely related to the permanent presence of the metal stent frame or polymer. Bioresorbable scaffolds have been developed to provide drug delivery an...
متن کاملIntraindividual Comparison of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Drug-Eluting Metallic Stents.
BACKGROUND The performance of everolimus-eluting bioresorbable vascular scaffold (BVS) versus drug-eluting metallic stent (DES) in the same individual receiving multilesion percutaneous coronary intervention (PCI) remains poorly studied. This report investigates the intraindividual performance of BVS and DES in patients receiving multilesion PCI and follow-up angiography. METHODS AND RESULTS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The New England journal of medicine
دوره 377 18 شماره
صفحات -
تاریخ انتشار 2017