Estimation of optimal pediatric chest compression depth by using computed tomography

نویسندگان

  • Soo Young Jin
  • Seong Beom Oh
  • Young Oh Kim
چکیده

OBJECTIVE This study aimed to compare the optimal chest compression depth for infants and children with that of adults when the simulated compression depth was delivered according to the current guidelines. METHODS A total of 467 consecutive chest computed tomography scans (93 infants, 110 children, and 264 adults) were reviewed. The anteroposterior diameter and compressible diameter (CD) for infants and children were measured at the inter-nipple level and at the mid-lower half of the spine for adults. Compression ratio (CR) to CD was calculated at simulated 1/4, 1/3, and 1/2 antero-posterior compressions in infants and children, and simulated 5- and 6-cm compressions in adults. RESULTS In adults, the CRs to CD at simulated 5- and 6-cm compression depth were 41.7±0.16%, 50.0±7.3% respectively. In children and infants, the CRs to CD at 1/3 chest compression were 55.1±2.4% and 51.8±2.4%, respectively, and at 1/2 chest compression, CRs were 82.7±3.7% and 77.7±3.6%, respectively. The CRs to CD of 4-cm compression depth in infants and 5-cm compression depth in children were 74.4±10.9%, 62.5±8.7%, respectively. The CRs to CD for children and infants were significantly higher than in adults (P<0.001). The CR to CD of 4-cm compression depth in children was almost similar to that of 6-cm compression depth in adults (50.0± 6.9% vs. 50.0±7.3%, P=0.985). CONCLUSION Current pediatric guidelines for compression depth are too deep compared to those in adults. We suggest using 1/3 of the anteroposterior chest diameter or about 4 cm in children and less than 4 cm in infants.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study

Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...

متن کامل

A local study on diagnostic reference levels estimation for children computed tomography

Introduction: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the nat...

متن کامل

The Depths from Skin to the Major Organs at Chest Acupoints of Pediatric Patients

Background. Acupuncture is applied to treat numerous diseases in pediatric patients. Few reports have been published on the depth to which it is safe to insert needle acupoints in pediatric patients. We evaluated the depths to which acupuncture needles can be inserted safely in chest acupoints in pediatric patients and the variations in safe depth according to sex, age, body weight, and body ma...

متن کامل

Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran

Background: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the national computed tomo...

متن کامل

Planelet Transform: A New Geometrical Wavelet for Compression of Kinect-like Depth Images

With the advent of cheap indoor RGB-D sensors, proper representation of piecewise planar depth images is crucial toward an effective compression method. Although there exist geometrical wavelets for optimal representation of piecewise constant and piecewise linear images (i.e. wedgelets and platelets), an adaptation to piecewise linear fractional functions which correspond to depth variation ov...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016