Variability and reliability of the pendulum test for spasticity using a Cybex II isokinetic dynamometer.
نویسنده
چکیده
I undertook this study to determine the test-retest variability and reliability of the pendulum test for muscle spasticity performed with the Cybex II isokinetic dynamometer. Thirty patients, with intracranial lesions and hemiplegia of 15 days' to 3 years' duration, were tested four times, consecutively. With the patients lying supine, the angle of flexion, at which the knee first reversed direction after the leg was dropped, was measured on each goniogram from the dynamometer chart recorder. The mean differences between the angles of reversal and the angles of maximum possible knee flexion (the relative angle of reversal) for the first through the fourth trials were 27.2, 27.0, 26.3, and 25.6 degrees, respectively. The relative angle of reversal did not differ significantly between trials. The mean difference between the largest and smallest relative angle of reversal for each of the subject's trials was 6.1 degrees. The intraclass correlation coefficient between the relative angle of reversal for the four trials was .96. Because the test variability was not significant and because the correlation between trials was high, the test may merit broader application to patients with intracranial lesions. Further investigation of variability across days and after treatments is advised.
منابع مشابه
Cybex II isokinetic dynamometer for the documentation of spasticity. Suggestion from the field.
Recent studies involving patients with CNS lesions have clearly demonstrated that agonist paresis rather than antagonist spasticity is the primary factor limiting torque production. The presence of spasticity can, nonetheless, be important because of its effect on the quality of movement and because of the propensity of spastic muscles toward contracture. Therefore, methods for more precisely d...
متن کاملEccentric and concentric isokinetic knee flexion and extension: a reliability study using the Cybex 6000 dynamometer.
OBJECTIVE To determine the reliability of the Cybex 6000 isokinetic dynamometer in measuring the knee muscle performance concentrically and eccentrically. METHODS 18 male and 12 female subjects with no previous knee injuries, who had not previously undergone any isokinetic testing, were studied. The flexor and extensor muscles groups of both knees were tested at 60 degrees s-1 and 120 degrees...
متن کاملA Validity Study of the Modified Tardieu Scale in Measruing Poststroke Knee Extensor Spasticity
Background & Aims: The Modified Tardieu Scale (MTS) is a clinical scale for measuring the degree of muscle spasticity. The aim of this study was to evaluate the validity of the MTS in measuring poststroke knee extensorspasticity. Methods: This was a cross-sectional study performed in 2012 at a university clinic of neurological physiotherapy in Tehran, Iran, with repeated measurements. In the pr...
متن کاملReliability of isokinetic Measures
Isokinetic resistance is frequently used to strength profile healthy athletes and to evaluate the status of injured athletes involved in rehabilitation programs. The purpose of this investigation was to determine the reliability of peak torque, torque acceleration energy, endurance ratio, average power, and total work measures obtained with a Cybex isokinetic dynamometer. Fifteen college studen...
متن کاملUse of a Cybex NORM dynamometer to assess muscle function in patients with thoracic cancer
BACKGROUND The cachexia-anorexia syndrome impacts on patients' physical independence and quality of life. New treatments are required and need to be evaluated using acceptable and reliable outcome measures, e.g. the assessment of muscle function. The aims of this study were to: (i) examine the acceptability and reliability of the Cybex NORM dynamometer to assess muscle function in people with n...