Does low-intensity pulsed ultrasound stimulate maturation of tissue-engineered cartilage?

نویسندگان

  • Georg N Duda
  • Alexander Kliche
  • Ralf Kleemann
  • Jan E Hoffmann
  • Michael Sittinger
  • Andreas Haisch
چکیده

Traumatic events are a primary cause of local lesions of articular cartilage. Tissue engineered, cartilage-like structures represent an alternative to current treatment methods. The time necessary for tissue maturation and the mechanical quality of the regenerate at implantation are both critical factors for clinical success. Low-intensity pulsed ultrasound has proven to accelerate chondrogenesis in vitro. The goal of this study was to evaluate whether low-intensity pulsed ultrasound is capable of accelerating the process of cartilage maturation and increasing regenerate stability. Hyaline-like cartilage specimens were generated in vitro and subcutaneously implanted in the backs of nude mice. Twenty-eight animals received 20 min of low-intensity pulsed ultrasound treatment daily, and 28 animals received a sham treatment. Specimens were explanted after 1, 3, 6, and 12 weeks, mechanically tested with the use of an indentation test, histologically examined, and processed for RT-PCR. The Young's moduli significantly increased from 3 to 12 weeks, and at 6 weeks were comparable to those of native articular cartilage. In histological examination, specimens showed neocartilage formation. There was no significant difference between ultrasound-treated and sham-treated groups. The mechanical stability of the neocartilage specimens increased with treatment time and reached values of native cartilage after 6 weeks in vivo. Low-intensity pulsed-ultrasound stimulation showed no stimulatory effect on tissue maturation. In contrast, ultrasound-treated specimens showed a reduced Col 2 expression at 1 week and were significantly less stiff compared to native cartilage at 6 and 12 weeks. An acceleration of the maturation of tissue-engineered neocartilage in a clinical setting by means of low-intensity pulsed ultrasound therefore appears rather unrealistic.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Low-Intensity Pulsed Ultrasound (LIPUS) on Cartilage Healing; A Preliminary Study

INTRODUCTION: Low-intensity pulsed ultrasound (LIPUS) stimulation has been observed to enhance bone formation, cartilage regeneration, and softtissue (tendon and muscle) healing. In particular, increased biosynthetic activity and chondrogenic differentiation of human mesenchymal stem cells were observed under LIPUS . However, optimal conditions (such as frequency, intensity and treatment durati...

متن کامل

Does ultrasound stimulate osteoconduction? A placebo-controlled single-blind study using collagen membranes in the rat mandible.

PURPOSE To investigate whether ultrasound can stimulate osteoconduction in the mandible, an attempt was made to stimulate the osteoconductive process with low-intensity pulsed ultrasound in rats. MATERIALS AND METHODS In 64 rats, a 5.0-mm diameter circular mandibular defect was made in the ramus and, subsequently, covered on both sides with collagen membranes. Two groups were studied, an ultr...

متن کامل

Low-Intensity Pulsed Ultrasound (LIPUS) Controllable LIPUS-Device – Labaratory Equipment for in vitro Research Work on Chondral Tissue

The osteochondral defects represent a major health problem. It is therefore important to improve the already established treatment methods and to develop new, more effective therapies. A new promising therapeutic approach offers the mechanobiological osteoinductive effect of low-intensity pulsed ultrasound (LIPUS), already established in the regenerative repair of bone fractures. Ultrasound bas...

متن کامل

THE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR

We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...

متن کامل

High intensity focused ultrasound as a tool for tissue engineering: Application to cartilage.

This article promotes the use of High Intensity Focused Ultrasound (HIFU) as a tool for affecting the local properties of tissue engineered constructs in vitro. HIFU is a low cost, non-invasive technique used for eliciting focal thermal elevations at variable depths within tissues. HIFU can be used to denature proteins within constructs, leading to decreased permeability and potentially increas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 68 1  شماره 

صفحات  -

تاریخ انتشار 2004