Compressive Deconvolution in Medical Ultrasound Imaging.dvi
نویسنده
چکیده
The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissions. Nevertheless, RF image spatial resolution, contrast and signal to noise ratio are affected by the limited bandwidth of the imaging transducer and the physical phenomenon related to US wave propagation. To overcome these limitations, several deconvolution-based image processing techniques have been proposed to enhance the ultrasound images. In this paper, we propose a novel framework, named compressive deconvolution, that reconstructs enhanced RF images from compressed measurements. Exploiting an unified formulation of the direct acquisition model, combining random projections and 2D convolution with a spatially invariant point spread function, the benefit of our approach is the joint data volume reduction and image quality improvement. The proposed optimization method, based on the Alternating Direction Method of Multipliers, is evaluated on both simulated and in vivo data.
منابع مشابه
Ultrasound compressive deconvolution with ℓP-Norm prior
It has been recently shown that compressive sampling is an interesting perspective for fast ultrasound imaging. This paper addresses the problem of compressive deconvolution for ultrasound imaging systems using an assumption of generalized Gaussian distributed tissue reflectivity function. The benefit of compressive deconvolution is the joint volume reduction of the acquired data and the image ...
متن کاملCompressive Sensing and Blind Image Deconvolution
In this paper, we summarize our recent results on simultaneous compressive sensing reconstruction and blind deconvolution of images, captured by a compressive imaging system introducing degradation of the captured scene by an unknown point spread function. © 2013 Optical Society of America OCIS codes: 100.3020, 100.1455, 100.3190
متن کاملTwo-dimensional Blind Deconvolution of Medical Ultrasound Images
This paper uses a new ultrasound tissue model to propose an ultrasound image deconvolution algorithm for improving the quality of ultrasound images. This model incorporates random fluctuations of the tissue signal within the received ultrasound RF echo signal, which has not been considered in the existing ultrasound imaging algorithms. To deal with the tissue image formation and noise reduction...
متن کاملBlind Deconvolution for Ultrasound Sequences Using a Noninverse Greedy Algorithm
The blind deconvolution of ultrasound sequences in medical ultrasound technique is still a major problem despite the efforts made. This paper presents a blind noninverse deconvolution algorithm to eliminate the blurring effect, using the envelope of the acquired radio-frequency sequences and a priori Laplacian distribution for deconvolved signal. The algorithm is executed in two steps. Firstly,...
متن کاملA New and General Method for Blind Shift-Variant Deconvolution of Biomedical Images
We present a new method for blind deconvolution of multiple noisy images blurred by a shift-variant point-spread-function (PSF). We focus on a setting in which several images of the same object are available, and a transformation between these images is known. This setting occurs frequently in biomedical imaging, for example in microscopy or in medical ultrasound imaging. By using the informati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015