Cone-beam computed tomography images of phantoms with simulating trabecular bone structure fabricated using micro-stereolithography.

نویسندگان

  • Munetaka Naitoh
  • Hiroko Kinoshita
  • Kenichi Gotoh
  • Eiichiro Ariji
چکیده

OBJECTIVE Phantoms with simulating mandibular trabecular bone structure fabricated using micro-stereolithography were applied for a quantitative evaluation of cone-beam computed tomography (CT) images. MATERIALS AND METHODS Phantoms with a three-dimensional lattice, in which a square pillar was set at 0.10, 0.20, 0.30 and 0.40 mm at the edge, spaced at 0.60 mm, were made of an acrylic resin using micro-stereolithography. Cone-beam CT with a 0.1 mm-cubic voxel was then performed, and a plot profile of voxel values was analyzed. RESULTS The plot profiles of seven peaks corresponding to pillars in phantoms with 0.20, 0.30 and 0.40 mm-pillars were visually observed in cone-beam CT images. However, peaks of corresponding pillars in the 0.10 mm-pillar phantom could not be distinguished. The differences between average measured and designed distance were very small. CONCLUSION Cone-beam CT images of phantoms with 0.20, 0.30 and 0.40 mm-pillars fabricated using microstereolithography were obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlations between fabric tensors computed on cone beam and microcomputed tomography images

Anisotropy measurements of 15 trabecular bone biopsies from the radius estimated by different fabric tensors on images acquired through cone beam computed tomography (CBCT) and micro computed tomography (micro-CT) are compared. The results show that the generalized mean intercept length (MIL) tensor performs better than the global gray-scale structure tensor (GST), especially when the von Mises...

متن کامل

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography.

PURPOSE The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. METHODS We measured the impact response of a dental implant placed into swine bone specimens composed of o...

متن کامل

Anisotropy Estimation of Trabecular Bone in Gray-Scale: Comparison Between Cone Beam and Micro Computed Tomography Data

Measurement of anisotropy of trabecular bone has clinical relevance in osteoporosis. In this study, anisotropy measurements of 15 trabecular bone biopsies from the radius estimated by different fabric tensors on images acquired through cone beam computed tomography (CBCT) and micro computed tomogRodrigo Moreno Department of Radiology and Department of Medical and Health Sciences Linköping Unive...

متن کامل

Anatomic Situation of Posterior Superior Alveolar Artery in Cone-Beam Computed Tomography Images in Maxillary Molar Region

Introduction: Bleeding is an important complication during implant placement. The aim of this study was to evaluate the anatomic situation of the posterior superior alveolar artery (PSAA) in cone-beam computed tomography (CBCT) images in maxillary molar region in an Iranian population. Methods: In this descriptive cross-sectional study, CBCT scans of the edentulous regions of the posterior max...

متن کامل

Trabecular bone structural parameters evaluated using dental cone-beam computed tomography: cellular synthetic bones

OBJECTIVE This study compared the adequacy of dental cone beam computed tomography (CBCT) and micro computed tomography (micro-CT) in evaluating the structural parameters of trabecular bones. METHODS The cellular synthetic bones in 4 density groups (Groups 1-4: 0.12, 0.16, 0.20, and 0.32 g/cm3) were used in this study. Each group comprised 8 experimental specimens that were approximately 1 cm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Okajimas folia anatomica Japonica

دوره 89 2  شماره 

صفحات  -

تاریخ انتشار 2012