Laser Desorption Solid Phase Microextraction

نویسنده

  • Yan Wang
چکیده

The use of laser desorption as a sample introduction method for solid-phase microextraction (SPME) has been investigated in this research project. Three different types of analytical instruments, mass spectrometry (MS), ion mobility spectrometry (IMS) and gas chromatography (GC) were employed as detectors. The coupling of laser desorption SPME to these three instruments was constructed and described in here. Solid-phase microextraction/surface enhanced laser desorption ionization fibers (SPME/SELDI) were developed and have been coupled to two IMS devices. SPME/ SELDI combines sampling, sample preparation and sample introduction with the ionization and desorption of the analytes. Other than being the extraction phase for the SPME fiber, the electroconductive polymer coatings can facilitate the ionization process without the involvement of a matrix assisted laser desorption/ionization (MALDI) matrix. The performance of the SPME coatings and the experimental parameters for laser desorption SPME were investigated with the SPME/SELDIIMS devices. The new SPME/SELDI-IMS 400B device has a faster data acquisition system and a more powerful data analysis program. The optimum laser operation parameters were 250 μJ laser energy and 20 Hz repetition rate. Three new SPME coatings, polypyrrole (PPY), polythiophene (PTH) and polyaniline (PAN) were developed and evaluated by an IMS and a GC. The PPY coating was found to have the best performance and was used in most of the experiments. The characteristics of the PPY and the PTH SPME/SELDI fiber were then assessed with both IMS iii and MS. Good linearity could be observed between the fiber surface area and the signal intensity, and between the concentration and the signal intensities. The ionization mechanism of poly(ethylene glycol) 400 (PEG) was studied with the SPME/SELDI-IMS 400B device. It was found that the potassiated ions and sodiated ions were both present in the ion mobility spectra. The results obtained with quadrupole time-of-flight (QTOF) MS confirmed the presence of both potassiated and sodiated ions. This result suggested that cationization is the main ionization process when polymers are directly ionized from the PPY coated silica surface. Four PEGs with different average molecular weights and poly(propylene glycol) 400 were also tested with this SPME/SELDI device. The differences between the ion mobility spectra of these polymers could be used for the fast identification of synthetic polymers. The SPME/SELDI fibers were then coupled to QTOF MS and hybrid quadrupole linear ion trap (QqLIT) MS, respectively. Improved sensitivity could be achieved with QqLIT MS, as the modified AP MALDI source facilitated the ion transmission. The application of method for analysis of urine sample and the bovine serum albumin (BSA) digest were demonstrated with both PPY and PTH fibers. The LOD for leucine enkephalin in urine was determined to be 40 fmol μL−1 with PTH coated fiber; and the LOD for the BSA digest was 2 fmol μL−1 obtained with both PTH and PPY fibers. A new multiplexed SPME/AP MALDI plate was designed and evaluated on the same QqLIT MS to improve the throughput, and the performance of this technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HCl- Etched Steel Fiber for Determination of Phthalates in Water Samples by Solid-Phase Microextraction

In the present work, a stainless steel wire was etched by hydrochloric acid during a chemical etching process. The obtained black layer on the surface of the fiber was used as sorbent for extraction of trace amount of phthalates in the aqueous samples by solid phase microextraction. New fiber efficiency was investigated using a home-made solid-phase microextraction (SPME) device and gas chr...

متن کامل

Determination of Volatiles in Beer using Solid-Phase Microextraction in Combination with Gas Chromatography/Mass Spectrometry

Kleinová J., Klejdus B. (2014): Determination of volatiles in beer using solid-phase microextraction in combination with gas chromatography/mass spectrometry. Czech J: Food Sci., 32: 241–248. Headspace solid phase microextraction and purge and trap analysis were used for the determination of volatiles in beer. These methods were compared with the analysis of unconcentrated gas phase and liquid ...

متن کامل

ZnO polythiophene SBA-15 nanoparticles as a solid-phase microextraction fiber for fast determination essential oils of Matricaria chamomilla

The objective of this study is determination the volatile compounds of Matricaria chamomilla of an inorganic–organic hybrid material based on ZnO nanoparticles anchored to a composite made from polythiophene and hexagonally ordered silica (ZnO/PT/SBA-15) as a solid-phase fiber microextraction (SPME). Microextraction techniques with nanoparticles ZnO/PT/SBA-15 resulted in a more efficient analyt...

متن کامل

Ordered nanoporous carbon (CMK-3) coated fiber for solid-phase microextraction of benzene and chlorobenzenes in water samples

Nanoporous carbons (CMK-3) were prepared and have been used as a fiber coating for headspace solid phase microextraction (HS-SPME). The prepared materials were characterized by Scanning Electron Microscopy (SEM), X-Ray Diffraction (XRD) and N2 adsorption/desorption isotherms. The efficiency of the fiber was evaluated using a gas chromatography (GC) system for the extraction of benzene (B) and c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006