چکیده
The construction and commissioning status of the Relativistic Heavy Ion Collider, RHIC, is discussed. Those novel features of a heavy ion Collider that are distinct from conventional hadron Colliders in general are noted. These features are derived from the experimental requirements of operation with a variety of ion species over a wide energy range including collisions between ions of unequal energies. The paper notes other challenging issues for the Collider including intrabeam scattering, interaction-region error compensation, magnet alignments, and matched transition-energy jump. The project is in the final few months of a seven-year construction cycle and is entering the commissioning phase. A review of the superconducting magnet program is given together with the status of the machine construction and commissioning.
منابع مشابه
P-187: Challenges of Commissioning Mothers in Iran for Selection of Surrogate Mothers
s:1640:"Background: Surrogacy is one of the most controversial procedures in infertility treatment. Despite increasing of using this technology in Iran, there are few practical data about surrogacy. There isn't any study assessing experiences of commissioning mothers about surrogate mother selection. The purpose of this study was exploring of commissioning mothers' experiences in sele...
متن کاملLHCb detector status and commissioning
The LHCb detector status and commissioning is presented.
متن کاملThe comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data
Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...
متن کاملCommissioning and early experience with a new generation low-energy linear accelerator in zahedan
Introduction: Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and pr...
متن کاملCommissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran
Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999