Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA).
نویسندگان
چکیده
Current parallel imaging techniques for accelerated imaging require a fully encoded reference data set to estimate the spatial coil sensitivity information needed for reconstruction. In dynamic parallel imaging a time-interleaved acquisition scheme can be used, which eliminates the need for separately acquiring additional reference data, since the signal from directly adjacent time frames can be merged to build a set of fully encoded full-resolution reference data for coil calibration. In this work, we demonstrate that a time-interleaved sampling scheme, in combination with autocalibrated GRAPPA (referred to as TGRAPPA), allows one to easily update the coil weights for the GRAPPA algorithm dynamically, thereby improving the acquisition efficiency. This method may update coil sensitivity estimates frame by frame, thereby tracking changes in relative coil sensitivities that may occur during the data acquisition.
منابع مشابه
Table I Normalized Artifact Indices KLT-GRAPPA: A New Method to Estimate Auto-Calibration Signal in Dynamic Parallel Imaging
Introduction: Parallel imaging techniques such as SENSE and GRAPPA [1, 2], are frequently used for dynamic imaging of physiological processes requiring high temporal resolution, such as cardiac cine or perfusion imaging. The performance of any parallel imaging technique depends on the accurate estimation of channel sensitivity. TSENSE and TGRAPPA are parallel acquisition methods that can dynami...
متن کاملA new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.
TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a sliding-window moving average when finding the autocalibrating signals. Both ...
متن کاملParallel MRI with Extended and Averaged Grappa Kernels (PEAK-Grappa): SNR optimized fast dynamic imaging with high acceleration factors
Introduction: In order to reduce total acquisition time or to increase spatiotemporal resolution in dynamic MRI several techniques such as TSENSE [1], TGrappa [2], kt-SENSE, kt-BLAST [3] and kt-Grappa [4] have recently been introduced. The combination of parallel MRI and temporal imaging acceleration permits the use of higher acceleration factors compared to conventional parallel imaging techni...
متن کاملOptimized parallel imaging for dynamic PC-MRI with multidirectional velocity encoding.
Phase contrast MRI with multidirectional velocity encoding requires multiple acquisitions of the same k-space lines to encode the underlying velocities, which can considerably lengthen the total scan time. To reduce scan time, parallel imaging is often applied. In dynamic phase contrast MRI using standard generalized autocalibrating partially parallel acquisitions (GRAPPA), several central k-sp...
متن کاملk-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor.
A novel technique called "k-t GRAPPA" is introduced for the acceleration of dynamic magnetic resonance imaging. Dynamic magnetic resonance images have significant signal correlations in k-space and time dimension. Hence, it is feasible to acquire only a reduced amount of data and recover the missing portion afterward. Generalized autocalibrating partially parallel acquisitions (GRAPPA), as an i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 53 4 شماره
صفحات -
تاریخ انتشار 2005