Abstract Submitted for the MAR13 Meeting of The American Physical Society Monte Carlo simulation of single-molecule recycling in a nanochannel for accurate diffusion measurements

نویسندگان

  • BO WANG
  • Bo Wang
چکیده

Submitted for the MAR13 Meeting of The American Physical Society Monte Carlo simulation of single-molecule recycling in a nanochannel for accurate diffusion measurements BO WANG, SULTAN BEHERY, LLOYD M. DAVIS, University of Tennessee Space Institute — In previous experiments on single-molecule (SM) detection in solution, we demonstrated that prolonged observation times and photon yields are achieved by actively trapping a molecule in a nanochannel. We also developed Monte Carlo simulations to optimize experimental parameters and improve real-time control algorithms. Other researchers have since shown similar advantages can be attained by alternating the flow in the nanochannel so that a SM repeatedly passes through the laser excitation focus and that variation in the times between detections provides a measure of the diffusion coefficient of the molecules. We have extended the previous simulations to study the SM recycling experiment and to compare control algorithms and measurement capabilities in which the timing of each photon is processed by an FPGA circuit, as used in our trapping experiments, with those where detected photons are first collected into 1 ms bins, as in the prior recycling experiments. We present capabilities for measuring the diffusion coefficients of SMs. Also, we compare the capability for resolving a solution containing species with differing diffusion coefficients with that of fluorescence correlation spectroscopy, which is often used for monitoring molecular interactions in pharmaceutical research. Bo Wang University of Tennessee Space Institute Date submitted: 14 Dec 2012 Electronic form version 1.4

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abstract Submitted for the MAR13 Meeting of The American Physical Society Simulation of Nanostructure and Thermal Conductivity in Binary Alloys

Submitted for the MAR13 Meeting of The American Physical Society Simulation of Nanostructure and Thermal Conductivity in Binary Alloys YUSUKE KONISHI, NRI-AIST, TETSUYA FUKUSHIMA, KAZUNORI SATO, HIROSHI KATAYAMA-YOSHIDA, Graduate School of Engineering Science, Osaka University, YOSHIHIRO ASAI, NRI-AIST — Thermoelectric materials attract much attention because of concerns about energy conservati...

متن کامل

Abstract Submitted for the SES07 Meeting of The American Physical Society Numerical modeling of single-molecule detection and trapping in a nanochannel

Submitted for the SES07 Meeting of The American Physical Society Numerical modeling of single-molecule detection and trapping in a nanochannel WILLIAM ROBINSON, ZBIGNIEW SIKORSKI, LLOYD M. DAVIS, UTSI — Confocal fluorescence microscopy with single-photon counting enables detection of individual fluorescent molecules as they randomly diffuse through a tightly focused laser beam. However, for man...

متن کامل

Abstract Submitted for the MAR13 Meeting of The American Physical Society Spin-orbit scattering in quantum diffusion of massive Dirac fermions

Submitted for the MAR13 Meeting of The American Physical Society Spin-orbit scattering in quantum diffusion of massive Dirac fermions WENYU SHAN, Wean Hall 6424, Carnegie Mellon University, 5000 Forbes Ave, Pittsburgh — We theoretically study the effects of spin-orbit scattering on weak (anti-)localization in two-dimensional massive Dirac systems. We clarify that weak anti-localization and loca...

متن کامل

Siemens primus accelerator simulation using EGSnrc Monte Carlo code and gel dosimetry validation with optical computed tomography system by EGSnrc code

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

متن کامل

Abstract Submitted for the MAR11 Meeting of The American Physical Society Spin-orbit interaction in quantum Monte Carlo LUBOS MITAS,

Submitted for the MAR11 Meeting of The American Physical Society Spin-orbit interaction in quantum Monte Carlo LUBOS MITAS, North Carolina State University, RENE DERIAN, Institute of Physics, Slovak Academy of Sciences, SHI GUO, North Carolina State University — For spinless Hamiltonians (ie, no explicit spin operators), real space quantum Monte Carlo (QMC) methods such as variational and fixed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013