Spot urine protein: creatinine ratio versus 24 hour urine protein at various levels of GFR patients referred to a tertiary care hospital of Pakistan.
نویسندگان
چکیده
OBJECTIVE To determine the correlation of "random single voided urine protein: creatinine ratio" to "twenty four hour urine protein" at different levels of glomerular filtration rate (GFR) in Pakistani population. METHODS A total of 107 patients were included in this cross section study. Patients were divided into five groups according to the GFR. Spot urine protein: creatinine ratio and 24 hour urine protein was measured by the standard methods. The correlation coefficient ( r) between the two was calculated in each group separately. RESULTS The GFR in groups 1 to 5 was > or =90, 60-89, 30-59, 15-29, and <15 ml/minute/1.73 m2 respectively. In group one correlation coefficient "r" was 0.96, in group two "r" was 0.81, in group three "r" was 0.94, in group four "r" was 0.82 and in group five "r" was 0.80. CONCLUSION "Random single voided urine protein: creatinine ratio" may be used as an alternative to "24 hour urine collection for protein" at all levels of GFR in Pakistani population.
منابع مشابه
Comparison of spot urine protein creatinine ratio with 24 hour urine protein for estimation of proteinuria.
The objective of our study was to evaluate and standardise the method of spot (random) urine protein creatinine ratio (UP/C) for estimation of proteinuria. The study contained 241 study participants in a tertiary care hospital inclusive of 208 cases and 33 normal volunteers. The 24 hour urine protein estimation was done on 24 hour urine samples and UP/C ratio was calculated on random urine samp...
متن کاملارزیابی کمی پروتئینوری با استفاده از نسبت پروتئین به کراتینین در نمونههای تصادفی ادرار افراد مبتلا به بیماریهای کلیوی
Quantitation of urinary protein excretion is important for diagnostic and prognostic purposes and to achieve the best treatment. The method most commonly used to measure urinary protein in 24 hour urine samples, are time consuming and often inaccurate. This study performed on 101 persons. Urine samples were collected three times aday. The protein/creatinine ratio(mg:mg) was measured and c...
متن کاملارزش تشخیصی نسبت پروتئین به کراتینین نمونهی ادرار تصادفی در بیماران مشکوک به پره اکلامپسی
Background and Objective: Pre-eclampsia is the most serious disease in high-risk pregnancies affecting women and their fetus which may be associated with severe maternal-fetal problems and even death. The symptoms of this disease are high blood pressure and proteinuria. Prompt diagnosis of the disease can be particularly important in preventing or minimizing the effects on the mother and the fe...
متن کاملA Comparison of 4- and 24-Hour Urine Samples for the Diagnosis of Proteinuria in Pregnancy
Background: Preeclampsia is a serious complication of pregnancy, and it is vital to diagnosis the condition as early as possible. Proteinuria is an important symptom of preeclampsia, and repeated urine analysis to screen for the condition is part of the standard antenatal care. The purpose of this study was to determine the correlation between 4- and 24-hour urine total protein values to examin...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JPMA. The Journal of the Pakistan Medical Association
دوره 58 9 شماره
صفحات -
تاریخ انتشار 2008