Overview of the Cornell Erl Injector Cryomodule

نویسندگان

  • H. Padamsee
  • B. Barstow
  • I. Bazarov
  • S. Belomestnykh
  • M. Liepe
  • R. L. Geng
  • V. Shemelin
  • C. Sinclair
  • K. Smolenski
  • M. Tigner
چکیده

The Laboratory for Elementary-Particle Physics, Cornell University, in collaboration with Jefferson Lab is exploring the potential of a Synchrotron Radiation User Facility based on a multi-GeV, low emittance, EnergyRecovery Linac (ERL) with a 100 mA CW beam[1]. The ERL injector will accelerate bunches from the electron source from 0.5 MeV to 5 MeV with minimal emittance growth. The injector and main linac of the ERL will be based on superconducting RF technology to provide CW operation. There will be one cryomodule with five 1300 MHz 2-cell cavities, each providing one MV of acceleration, corresponding to an accelerating field of about 4.3 MV/m in CW operation. Besides standard features such as an integrated helium vessel and mechanical tuner, each cavity has two input couplers, symmetrically placed on the beam pipe to cancel kicks due to coupler fields. For a 100 mA maximum injected beam current, each coupler must deliver 50 kW of beam power leading to a Qext of 4.6 x10 for matched beam loading conditions. Antennaand loop-based HOM couplers can disturb beam emittance through kicks. We plan to avoid the use of such couplers. Following the strategy for B-factory SRF cavities, the beam pipe aperture has been enlarged on one side to propagate all higher order modes out to symmetric ferrite beam pipe loads. These are positioned outside the helium vessel and cooled to liquid nitrogen temperature. Ferrite properties at 77 K have been measured and the corresponding damping evaluated. To explore the full capabilities of the injector, energy gains up to 3 MV per cavity will be considered at lower beam currents. For this flexibility, the input coupling needs to be adjustable by a factor of 9.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Brightness, High Current Injector Design for the Cornell Erl Prototype∗

Cornell University, in collaboration with Jefferson Laboratory, has proposed the construction of a 100 MeV, 100 mA CW Energy Recovery Linac (ERL) prototype, to study and resolve the many accelerator physics and technology issues of this type of machine. The long term goal of this work is the construction of a state-of-the-art 5 to 7 GeV ERL-based synchrotron light source. A key element of this ...

متن کامل

Berlinpro Booster Cavity Design, Fabrication and Test Plans

The bERLinPro project, a 100 mA, 50 MeV superconducting RF (SRF) Energy Recovery Linac (ERL) is under construction at Helmholtz-Zentrum Berlin for the purpose of studying the technical challenges and physics of operating a high current, c.w., 1.3 GHz ERL. This machine will utilize three unique SRF cryomodules for the injector, booster and linac module respectively. The booster cryomodule will c...

متن کامل

Booster Cavity Design, Fabrication and Test Plans

The bERLinPro project, a 100 mA, 50 MeV superconducting RF (SRF) Energy Recovery Linac (ERL) is under construction at Helmholtz-Zentrum Berlin for the purpose of studying the technical challenges and physics of operating a high current, c.w., 1.3 GHz ERL. This machine will utilize three unique SRF cryomodules for the injector, booster and linac module respectively. The booster cryomodule will c...

متن کامل

Design and Performance of the Cornell ERL DC Photoemission Gun

Cornell University is planning to build an Energy Recovery Linac (ERL) X-ray facility. For an ERL, it is well known that the x-ray beam brightness for the users is mainly determined by the initial electron beam emittance provided by the injector To address technical challenges of producing very low emittance beams at high average current as required for an ERL, Cornell University has proposed a...

متن کامل

First Tests of the Cornell University Erl Injector*

Cornell University is planning to build an Energy Recovery Linac (ERL) X-ray facility. For an ERL, it is well known that the x-ray beam brightness for the users is mainly determined by the initial electron beam emittance provided by the injector. To address technical challenges of producing very low emittance beams at high average current as required for an ERL, Cornell University has proposed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003