Comparing Radiation Dose from Conventional Fluoroscopy to Intraoperative Cone Beam CT (O-arm) during Percutaneous Lesioning Procedures of the Gasserian Ganglion

نویسندگان

  • Alexander Muacevic
  • John R Adler
  • Sohum Desai
  • Vishal J Patel
  • Rishi R Lall
  • Daniel Branch
  • Achal P Patel
  • Randall Z Allison
  • David Paulson
  • Juan R Ortega-Barnett
چکیده

INTRODUCTION The use of intraoperative CT-guidance during the percutaneous treatment of trigeminal neuralgia has become increasingly popular due to the greater ease of foramen ovale cannulation and decreased procedure times. Concerns regarding radiation dose to the patient, however, remain unaddressed. We sought to compare the emitted radiation dose from fluoroscopy with intraoperative CT for these procedures. METHODS A retrospective review of percutaneous lesioning procedures for trigeminal neuralgia performed between 2010 until 2012 at our institution was conducted and radiation doses to the patient were recorded. We subsequently simulated four separate percutaneous trigeminal rhizotomies using the O-arm intraoperative CT (Medtronics, Minneapolis, MN, USA) to cannulate the foramen ovale bilaterally in two formalin-fixed cadaver heads. RESULTS Seventeen successful percutaneous treatments for trigeminal neuralgia were performed during the study period. Eleven procedures containing complete records were included in the final analysis. For procedures using fluoroscopy, the mean dosage was 15.2 mGys (range: 1.15 - 47.95, 95% CI 7.34 - 22.99). Radiation dosage from the O-arm imaging system was 16.55 mGy for all four cases. An unequal variance t-test did not reach statistical significance (p=0.42). CONCLUSIONS We did not observe a significant difference in radiation dose delivered to subjects when comparing CT-guided foramen ovale cannulation relative to fluoroscopy for percutaneous lesioning of the Gasserian ganglion. Additional study is required under operational settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

C-arm fluoroscopic cone beam CT for guidance of minimally invasive spine interventions.

BACKGROUND Isocentric C-arm fluoroscopic cone beam CT (CBCT) is a new technique for near real time 3-D volume imaging guidance of percutaneous interventional procedures. In combination with digital flat panel detectors, CBCT has high spatial resolution with isotropic voxel size, allowing for high resolution image reconstruction in any plane, including 3D rotational reconstructions. CBCT combine...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

Purpose Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with th...

متن کامل

Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)

Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...

متن کامل

بررسی مقایسه‌ای دوز جذبی اشعه در اندام‌های هدف درتصویربرداری از ناحیه فک و صورت با تکنیک‌های پانورامیک، توموگرافی خطی، CBCT و CT پزشکی

Background and Aim: The objective of this study was to measure and compare the tissue absorbed dose in thyroid gland, salivary glands, eye and skin in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography (CBCT) and computed tomography (CT).Materials and Methods: Thermoluminescent dosimeters (TLD) were implanted in 14 sites of RANDO phantom to measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015