Detailed Studies of Pixelated CZT Detectors Grown with the Modified Horizontal Bridgman Method

نویسندگان

  • I. Jung
  • H. Krawczynski
  • M. Groza
چکیده

The detector material Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over a broad energy range, several keV up to some MeV. Presently, there are two main methods to grow CZT crystals, the Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB) process. The study presented in this paper is based on MHB CZT substrates from the company Orbotech Medical Solutions Ltd. [1]. Former studies have shown that high-work-function materials on the cathode side reduce the leakage current and therefore improve the energy resolution at lower energies. None of the studies have emphasized on the anode contact material. Therefore, we present in this paper the result of a detailed study in which for the first time the cathode material was kept constant and the anode material was varied. We used four different anode materials : Indium, Titanium, Chromium and Gold, metals with work-functions between 4.1 eV and 5.1 eV. The detector size was 2.0×2.0×0.5 cm with 8×8 pixels and a pitch of 2.46 mm. The best performance was achieved with the low work-function materials Indium and Titanium with energy resolutions of 2.0 keV (at 59 keV) and 1.9 keV (at 122 keV) for Titanium and 2.1 keV (at 59 keV) and 2.9 keV (at 122 keV) for Indium. Taking into account the large pixel pitch of 2.46 mm, these resolutions are very competitive in comparison to those achieved with detectors made of material produced with the more expensive conventional HPB method. We present a detailed comparison of our detector response with 3-D simulations. The latter comparisons allow us to determine the mobility-lifetime-products (μτ -products) for electrons and holes. Finally, we evaluated the temperature dependency of the detector performance and μτ -products. For many applications temperature dependence is important, therefore, we extended the scope of our study to temperatures as low as -30◦C. There are two important results. The breakdown voltage increases with decreasing temperature, and electron mobility-life-time-product decreases by about 30% over a range from 20◦C to -30◦C. The latter effect causes the energy resolution to deteriorate, but the concomitantly increasing breakdown voltage makes it Preprint submitted to Elsevier 2 February 2008 possible to increase the applied bias voltage and restore the full performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Gold Contacted Flip-chip Detectors with IMARAD CZT

We present initial results from our evaluation of a gold-contacted pixellated detector using cadmium zinc telluride substrate produced by IMARAD Imaging Systems. The Horizontal Bridgman (HB) grown crystals from IMARAD have been shown to produce high resolution photopeaks, but they are also seen to have large leakage current. Our previous tests with IMARAD CZT showed that the use of indium anode...

متن کامل

رشد تک‌بلور نیمرسانای Te04/0Zn96/0Cd به دو روش بریجمن تغییریافته و ترابری فاز بخار

Single crystals of Cd.96Zn.04Te (CZT) with 14 mm in diameter were grown by seedless modified Bridgman method. Also, crystals with the same chemical composition were grown by vapor phase inert gas-transport method (VPGT), and single crystals up to 3.5 mm in diameter were obtained. Structural studies by XRD and back reflection Laue method show that the grown crystals are single phase with high pu...

متن کامل

Charge sharing in common-grid pixelated CdZnTe detectors

The charge sharing effect in pixelated CdZnTe (CZT) detectors with a common anode steering grid has been studied. The impact on energy resolution of weighting potential cross-talk and ballistic deficit due to cathode signal shaping has been investigated. A detailed system modeling package considering charge induction, electronic noise, pulse shaping, and ASIC triggering procedures has been deve...

متن کامل

Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...

متن کامل

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008