Automated separation and measurement of lactate dehydrogenase isoenzymes.

نویسندگان

  • M G Busby
  • P J Kudirka
  • R N Carey
  • E C Toren
چکیده

We describe a totally automated, computer-controlled system for separating and measuring the activity of lactate dehydrogenase (EC 1.1.1.27) isoenzymes. These isoenzymes in tissue extracts were separated on disposable DEAE-cellulose mini-columns. Resolution was complete except that LD-1 was not resolved from LD-2.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation of rat lactate dehydrogenase isoenzyme C4 from other isoenzymes by affinity and ion-exchange chromatography.

Lactate dehydrogenase C, an isoenzyme composed of C polypeptide subunits and found only in mature testes and spermatozoa, differs kinetically, chemically and immunologically from the five common isoenzymes of lactate dehydrogenase, each of which is a tetramer of A and/or B subunits. In the rat lactate dehydrogenase C exists in two molecular forms, isoenzymes C4 and A1C3. In addition to these tw...

متن کامل

Simultaneous separation of serum creatine kinase and lactate dehydrogenase isoenzymes by ion-exchange column chromatography.

Lactate dehydrogenase isoenzymes were partially separated by use of a previously described column technique for creatine kinase [Clin. Chem. 20, 36 (1974)]. Extracts of lactate dehydrogenase-rich tissues were used to evaluate column resolution. Samples layered on mini-columns containing DEAE-Sephadex were eluted with Tris-buffered sodium chloride (100 and 200 mmol/liter). Lactate dehydrogenase ...

متن کامل

High-pressure liquid-chromatographic separation of lactate dehydrogenase isoenzymes.

The isoenzymes of lactate dehydrogenase (EC 1.1.1.27) were separated with excellent resolution in less than 1 h by high-pressure anion-exchange chromatography. These isoenzymes were determined in some tissue extracts and high-activity serum samples by this technique.

متن کامل

The Staining of Lactic Dehydrogenase Isoenzymes after Electrophoretic Separation on Cellulose Acetate.

Established electrophoretic techniques for the separation of the lactate dehydrogenase (L.D.H.) isoenzymes of tissues and body fluids, although of value in clinical medicine, are too elaborate for most routine laboratories. A simple method for the separation of these isoenzymes on cellulose acetate and their histochemical staining is described. Spectrophotometric estimations of the total L.D.H....

متن کامل

New developments in analysis of isoenzymes separated by "high-performance" liquid chromatography.

We have developed two enzyme analyzers for use in "high-performance" liquid chromatography. In both systems two detectors are used, placed after the column effluent has been combined with assay reagent. In one system, an absorbance detector is placed before and after a post-column reaction coil. Peaks observed at one detector are subtracted from those at the other, to produce a two-point measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 1976