Epi Distortion Correction by Constrained Nonlinear Coregistration Improves Group Fmri

نویسندگان

  • E. Visser
  • S. Qin
  • M. P. Zwiers
چکیده

Introduction Because of its short volume acquisition time, echo planar imaging (EPI) has remained the method of choice for most fMRI studies. A well-known problem with EPI are geometric distortions caused by magnetic susceptibility inhomogeneities in the field of view. Especially in the frontal part of the brain, this can cause activation to appear at an offset along the phase encoding (PE) direction from its true location. Additionally, as the distortions tend to vary in severity between subjects and interfere with affine coregistration, activation at the group level can suffer from the resultant registration errors. We show that unwarping the EPI images to match a distortion-free anatomical image using a method similar to [1] can reduce these problems and improve the sensitivity of the statistical analysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of T1 versus EPI spatial normalization templates for fMRI data analyses

Spatial normalization of brains to a standardized space is a widely used approach for group studies in functional magnetic resonance imaging (fMRI) data. Commonly used template-based approaches are complicated by signal dropout and distortions in echo planar imaging (EPI) data. The most widely used software packages implement two common template-based strategies: (1) affine transformation of th...

متن کامل

Image distortion correction in fMRI: A quantitative evaluation.

A well-recognized problem with the echo-planar imaging (EPI) technique most commonly used for functional magnetic resonance imaging (fMRI) studies is geometric distortion caused by magnetic field inhomogeneity. This makes it difficult to achieve an accurate registration between a functional activation map calculated from an EPI time series and an undistorted, high resolution anatomical image. A...

متن کامل

Assessment and improvement of fMRI normalization based on inversion-recovery prepared high-resolution EPI

Introduction Echo-planar imaging (EPI), used in most functional MRI (fMRI) studies, has several major limitations, including 1) geometric distortion, 2) low spatial-resolution, and 3) low anatomic resolvability, as compared with structural MRI data. Because of these limitations, it is difficult to accurately register EPI based fMRI data to structural images. For the same reasons, it remains cha...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

The clinical relevance of distortion correction in presurgical fMRI at 7T

Presurgical planning with fMRI benefits from increased reliability and the possibility to reduce measurement time introduced by using ultra-high field. Echo-planar imaging suffers, however, from geometric distortions which scale with field strength and potentially give rise to clinically significant displacement of functional activation. We evaluate the effectiveness of a dynamic distortion cor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009