Computational Analysis of Blood Flow Characteristics in an Aortic System with Abdominal and Left Common Iliac Aneurysm Pre- and Post-Stent Grafting
نویسندگان
چکیده
The aim of this study was to demonstrate how fluid dynamic parameters are affected by aortic geometry and flow condition in two cases. Case A included blood flow analysis in aortic system with abdominal aortic aneurysm and left common iliac aneurysm before stent graft placement, while in case B was included stent graft geometry, at the site of the aneurysms. An individual patient-specific geometry and a 3D finite element meshes were reconstructed, based on Computed tomography (CT) scan images. The analysis was performed using the possibilities of computational fluid dynamics. It uses numeric methods and algorithms for the simulation of blood flow by solving the Navier-Stokes equations on computational meshes. The computational simulations of cardiac cycles were performed for average blood properties and blood flow rate. The velocity field, pressure and shear stress, as main fluid dynamics parameters, were visualized and compared for cases A and B.
منابع مشابه
Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent
Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...
متن کاملAorto-Uni-Iliac Stent Grafting and Femoro-Femoral Bypass in a Patient with a Failed and Catastrophic Endovascular Aortic Aneurysm Repair
A 78-year-old man presented at Eulji University Hospital due to an abdominal aortic aneurysm with maximum diameter of 52 mm, which had been increased from 45 mm over 6 months. He underwent embolization of the left internal iliac artery with vascular plug, prior to endovascular abdominal aortic repair with a bifurcated stent graft system. Unfortunately, the inserted vascular plug was maldeployed...
متن کاملExternal iliac artery-to-internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting.
PURPOSE To describe four patients with abdominal aortic aneurysm and bilateral common iliac artery aneurysms repaired by coil embolization of the ipsilateral internal iliac artery, aortouniiliac endograft extended to the ipsilateral external iliac artery, femorofemoral bypass grafting, and a contralateral external iliac to internal iliac stent graft to preserve pelvic perfusion. METHODS Four ...
متن کاملEndovascular repair of ruptured abdominal aortic aneurysm (REVAR) for Type I Endoleak Post open repair
A 69 year old gentleman with a background history of previous coronary artery bypass graft underwent open abdominal aortic aneurysm repair for a 9 cm symptomatic juxta renal aortic aneurysm with a 20 mm dacron graft 14 years ago. He had pneumonia and pseudomembranous colitis post operatively but recovered completely and was discharged home. He returned within 2-3 weekswith abdominal and back pa...
متن کاملUsing a Surgeon-modified Iliac Branch Device to Preserve the Internal Iliac Artery during Endovascular Aneurysm Repair: Single-center Experiences and Early Results
BACKGROUND To evaluate the feasibility of a new surgeon-modified iliac branch device (IBD) technique to maintain pelvic perfusion in the management of common iliac artery (CIA) aneurysm during endovascular aneurysm repair (EVAR). METHODS From January 2011 to December 2013, a new surgeon-modified IBD technique was performed in department of vascular surgery of Peking Union Medical College Hosp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -