Comparative Experimental Analysis of the Thermal Performance of Evacuated Tube Solar Water Heater Systems With and Without a Mini-Compound Parabolic Concentrating (CPC) Reflector(C < 1)

نویسندگان

  • Gang Pei
  • Guiqiang Li
  • Jie Ji
  • Yuehong Su
چکیده

Evacuated tube solar water heater systems are widely used in China due to their high thermal efficiency, simple construction requirements, and low manufacturing costs. CPC evacuated tube solar water heaters with a geometrical concentration ratio C of less than one are rare. A comparison of the experimental rig of evacuated tube solar water heater systems with and without a mini-CPC reflector was set up, with a series of experiments done in Hefei (31°53'N, 117°15'E), China. The first and second laws of thermodynamics were used to analyze and contrast their thermal performance. The water in the tank was heated from 26.9 to 55, 65, 75, 85, and 95 °C. Two types of solar water heater systems were used, and the data gathered for two days were compared. The results show that when attaining low temperature water, the evacuated tube solar water heater system without a mini-CPC reflector has higher thermal and exergy efficiencies than the system with a mini-CPC reflector, including the average and immediate values. On the other hand, when attaining high temperature water, the system with a mini-CPC reflector has higher thermal and exergy efficiencies than the other one. The comparison presents the advantages of evacuated tube solar water heater systems with and without a mini-CPC OPEN ACCESS Energies 2012, 5 912 reflector, which can be offered as a reference when choosing which solar water system to use for actual applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran

This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of ...

متن کامل

Investigating the effect of hot water consumption profile on the performance of solar water heating systems

In this paper, a forced circulation solar water heater system is simulated for different hot water consumption profiles using flat plate collectors as well as evacuated tube collectors. The profiles studied are the actual samples of hot water consumption profiles for different commercial centers and institutions. Dynamic simulation outputs of system thermal performance are used as economic anal...

متن کامل

Carbon dioxide as working fluid for medium and high-temperature concentrated solar thermal systems

This paper explores the benefits and drawbacks of using carbon dioxide in solar thermal systems at medium and high operating temperatures. For medium temperatures, application of CO2 in non-imaging-optics based compound parabolic concentrators (CPC) combined with evacuated-tube collectors is studied. These collectors have been shown to obtain efficiencies higher than 40% operating at around 200...

متن کامل

Design and Optical Performance of Compound Parabolic Solar Concentrators with Evacuated Tube as Receivers

Abstract: In the present article, six symmetric compound parabolic solar concentrators (CPCs) with all-glass evacuated solar tubes (EST) as the receiver are designed, and a comparative study on their optical performance is performed based on theoretical analysis and ray-tracing simulations. In terms of optical loss through gaps of CPCs and optical efficiency averaged for radiation over the acce...

متن کامل

Application of Solar Thermal Collectors to Improve the Energy Performance of the Fresh Air HVAC Systems

&nbsp;In the preset study, the performance of a solar assisted heating, ventilation and air conditioning (HVAC) system in an operating theater building was studied. The yearly performances of the existing HVAC system and the system with the added solar collectors were simulated in terms of energy consumption and provided air conditions using a transient system simulation software (TRNSYS). In t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012