Method to Diagnose Window Failures and Measure U-factors on Site
نویسندگان
چکیده
Windows are an essential part of buildings due to the requirement for natural light, views, and fresh air. However, windows are thermally the weakest bridge in a building due to their high thermal conductivity. Therefore, window U-factor (thermal transmittance) information is indispensable in calculating the overall energy load of a building. U-factors of windows, however, are difficult to obtain on-site because the label mounted on a window exhibiting its U-factor is typically removed after its installation. Further, it is almost impossible to detect any of a variety of window failures, such as the loss of insulating gases, leaky or cracked windows, and localized air leakage, simply by visual inspection. In this study, a novel technique to measure window U-factor in the field by measuring four temperatures (interior and exterior air temperatures, and interior and exterior window surface temperatures) is presented. Experimental and field tests on various types of full-scale windows have been performed to obtain their field-measured U-factors. Experimental results show that the field-measured U-factors match within 8% of the rated U-factors of the windows. Several assemblies combining storm windows with singleor double-pane windows were tested and the combined U-factors of the assemblies were measured and the readings were compared with the U-factors estimated by ASHRAE. In another test, argon from a double-pane window was removed deliberately and results confirmed the leakage using the proposed method. In addition, field tests at five different buildings were performed and the comparison between measured and rated (or estimated) U-factors is presented. 5
منابع مشابه
COVID-19: A Window of Opportunity for Positive Healthcare Reforms
The current coronavirus disease 2019 (COVID-19) pandemic is testing healthcare systems like never before and all efforts are now being put into controlling the COVID-19 crisis. We witness increasing morbidity, delivery systems that sometimes are on the brink of collapse, and some shameless rent seeking. However, besides all the challenges, there are also possibilities t...
متن کاملEffect of Residual Stress on Failure of Tube-to-tubesheet Weld in Heat Exchangers
In a shell and tube heat exchanger, the failure of tube-to-tubesheet welds results in high-pressure water jet which erodes the refractory in front of the tubesheet. Finite element method was employed to simulate the welding process and post weld heat treatment (PWHT) to find the factors affecting the failure in tube-to-tubesheet weldments. Residual stresses in two different geometries of tube-t...
متن کاملRisk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study
Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...
متن کاملPrediction of Noise Transmission Loss and Acoustic Comfort Assessment of a Ventilated Window using Statistical Energy Analysis
In this paper, a novel analytical method was developed based on statistical energy analysis framework to evaluate sound transmission loss through ventilated windows. The proposed method was compared to numerical and analytical models available in the literature. Results showed the success and advantage of the proposed model in predicting the acoustic performance of the ventilated window and the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -