Three–Dimensional Force Analysis of Gait of a Trans-Femoral Amputee with Prosthesis
نویسنده
چکیده
Background: Prosthetic devices should provide proper alignment of segments and joints for efficient gait. Rehabilitation specialists should carefully assess the best fit of prosthesis for proper force distribution and comfort. The purpose of this paper was to examine the three-dimensional forces of a permanent prosthesis compared with the temporary prosthesis of an amputee during gait. Case description: A 58-year-old female, trans-femoral amputee, who was diagnosed with kidney disease, diabetes, and heart disease, consented to be a subject. The patient was tested for three-dimensional forces of gait wearing temporary prosthesis and the same test was performed three months later with a newly designed (permanent) prosthesis. Results: The results indicated that the patient had increased anterio-posterior and push-off forces with the permanent prosthesis. In addition, the medio-lateral forces were reduced which resulted in better balance during gait. Conclusions: Rehabilitation specialists should fit the prosthetic devices to the patients rather than fitting the patients to the prosthesis. In this study, the force analysis of gait was beneficial in assessing the best fit of prosthesis. Therefore, motion analysis should be performed to observe any deviations in balance, gait, and force distribution.
منابع مشابه
An Affordable Insole-Sensor-Based Trans-Femoral Prosthesis for Normal Gait
This paper proposes a novel and an affordable lower limb prosthesis to enable normal gait kinematics for trans-femoral amputees. The paper details the design of a passive prosthesis with magneto-rheological (MR) damping system and electronic control. A new control approach based on plantar insole feedback was employed here. Strategically placed sensors on the plantar insole provide required inf...
متن کاملFeature User-adaptivecontrolof a magnetorheological prosthetic knee
A magnetorheological knee prosthesis is presented that automatically adapts knee damping to the gait of the amputee using only local sensing of knee force, torque, and position. To assess the clinical effects of the user-adaptive knee prosthesis, kinematic gait data were collected on four unilateral trans-femoral amputees. Using the user-adaptive knee and a conventional, non-adaptive knee, gait...
متن کاملA comparative study of the physiological costs of walking in ten bilateral amputees.
The physiological cost of walking is greater in bilateral amputees (BA) than in both unilateral amputee and non-pathological gait. The aim of this study was to describe the physiological costs and other standard gait characteristics in a sample population of BA, walking at self-selected (comfortable) speeds. Amputees had bilateral trans-tibial, bilateral trans-femoral or trans-tibial/trans-femo...
متن کاملThe effect of changing the inertia of a trans-tibial dynamic elastic response prosthesis on the kinematics and ground reaction force patterns.
The aim of this study was to assess, by means of gait analysis, the effect on the gait of a trans-tibial amputee of altering the mass and the moment of inertia of a dynamic elastic response prosthesis. One male amputee was analysed for four to five walking trials at normal and fast cadences, using the VICON system of motion analysis and an AMTI force plate. The kinematic variables of cadence, s...
متن کاملEffect of prosthetic ankle units on the gait of persons with bilateral trans-femoral amputations.
In able-bodied individuals, the ankle joint functions to provide shock absorption, aid in foot clearance during the swing phase, and provides a rocker mechanism during stance phase to facilitate forward progression of the body. Prosthetic ankles currently used by persons with lower limb amputations provide considerably less function than their anatomical counterparts. However, increased ankle m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016