Assessment of radiation safety instructions to patients based on measured dose rates following prostate brachytherapy.

نویسندگان

  • Lawrence T Dauer
  • Michael J Zelefsky
  • Christopher Horan
  • Yoshiya Yamada
  • Jean St Germain
چکیده

PURPOSE To validate radiation safety instructions to patients and to evaluate the potential radiation doses to members of the public after (125)I or (103)Pd prostate implantation. METHODS AND MATERIALS Radiation dose rate measurements were made in the immediate postoperative period on 636 consecutive patients with stage T1-T2 prostate cancer who underwent transperineal (125)I or (103)Pd implantation at Memorial Sloan-Kettering Cancer Center during the period from August 1995 through January 2003. RESULTS The mean radiation dose rate at the anterior skin surface following a prostate implant was 37 microSv/hr for (125)I and 8 microSv/hr for (103)Pd. At 30 cm from the anterior skin surface, these dose rates were reduced to 6 microSv/hr for (125)I and 3 microSv/hr for (103)Pd. At 1 m from the anterior skin surface the dose rates from both types of implants were reduced to less than 1 microSv/hr. The effect of body weight on dose rates from (125)I sources was examined for a select sub-group of patients and the measured dose rate was found to decrease with increasing body weight. In another group of patients, dose rate measurements were made on both lateral skin surfaces and were less than 16.8 microSv/hr in all cases. Assuming a 33% occupancy factor and utilizing the mean measured dose rate for (125)I, the time required to reach an effective dose equivalent limit of 5 mSv for caregivers was estimated to be 19 days on contact with the skin surface. Using a similar calculation, the lifetime doses for (125)I at a distance of 30 cm from the anterior skin surface, as well as the lifetime doses for (103)Pd on contact with the skin surface and at 30 cm from the anterior skin surface can be shown to be less than 5 mSv. CONCLUSIONS The large number of cases available for this study permits a validation of radiation safety recommendations and provides concrete information from which the permitted exposure times following implantation can be estimated. The data support the conclusion that patients treated with these implants do not represent a radiation risk to members of the public.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Historical review of interstitial prostate brachytherapy

In the recent years, interstitial brachytherapy implantation has become the treatment of choice for early stage prostate cancer patients. Treatment of prostate cancer with radiation is traced back to 1909. Originally this treatment modality was very crude and could not gain much popularity till 1982. Advancements in radioactive source designs, introduction of new low energy radioactive sources,...

متن کامل

Feasibility and safety of outpatient brachytherapy in 37 patients with brain tumors using the GliaSite® Radiation Therapy System.

Temporary, low dose rate brachytherapy to the margins of resected brain tumors, using a balloon catheter system (GliaSite® Radiation Therapy System) and liquid I-125 radiation source (Iotrex™), began in 2002 at the University of Arizona Medical Center. Initially, all patients were treated on an inpatient basis. For patient convenience, we converted to outpatient therapy. In this article we revi...

متن کامل

Assessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method

Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...

متن کامل

Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans

Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brachytherapy

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2004